Ingersoll-Rand RR100 Series Скачать руководство пользователя страница 2

80235740_ed1

Description

The RR100-F30-D includes air valve and regulator functions.

The RR100-F30-D is made of three main components:

The master regulator which sets the pilot pressure.

The solenoid valve which will open or close the system when the 

operator actuates the switch key.

The slave regulator which is the main body.

The slave regulator will receive the signal from the master regulator 

through the solenoid valve. For pre-engage starters the signal 

pressure will come from the master regulator through the solenoid 

valve to the pilot “In” port of the air starter drive housing, giving the 

signal to engage the drive pinion into the ring gear. After engaging 

the drive pinion, air will come out through the “Out” port of the drive 

housing and will go to the cap of the slave regulator.

1.

2.

3.

The slave regulator using the pressure signal on top of the upper 

piston will force the valve piston off its seat. That allows air to flow 

into the control chamber below the upper piston, through the 

outlet port of the RR100 valve to the starter motor. Outlet pressure 

increases in the downstream system and sensing chamber (under 

the upper piston) and applies an upward force on the bottom of 

the upper piston. The upper piston and valve piston move upward. 

Upward movement stops when the forces below the upper piston 

balance the force above the upper piston.

WARNING

Do not use this starter relay valve with natural gas or other 

flammable gases.

Operation

Clockwise rotation of screw (1) will open the seat in the master 

regulator and will increase the pressure between the master 

regulator and solenoid valve (2). Do not try to exceed 11 bar or 160 

psig (or slightly higher than the working pressure of the starter). 

The pressure you adjust at the slave regulator will be slightly higher 

than the working pressure at the starter. In order to easily adjust the 

working pressure install a gauge on the gauge port.

2

1

(Dwg. 45534005)

The master pressure regulator is designed as a relieving regulator. 

When the pressure below the diaphragm reaches 1.5 bars over the 

adjusted pressure, the regulator exhausts the excess pressure.

(Dwg. 45532504)

(Dwg. 45533866)

Содержание RR100 Series

Страница 1: ...80235740 Edition1 June 2007 Save These Instructions Starter Relay Valve RR100 Installation and Maintenance Information...

Страница 2: ...he upper piston through the outlet port of the RR100 valve to the starter motor Outlet pressure increases in the downstream system and sensing chamber under the upper piston and applies an upward forc...

Страница 3: ...ge Head Outlet Inlet Dwg 45534021 Schematics Piping Diagram Master Regulator For Inertia Drive Applications For Pre Engaged Drive Applications Out In Safety Valve Optional Slave Regulator Gage Optiona...

Страница 4: ...lled on a steel pipe in a remote location Apply SMB 441 Ingersoll Rand Sealant to the tapped inlet of Flange ST400 18 Tighten the ST400 18 flange on the steel pipe to 80 Nm torque If desired connect a...

Страница 5: ...um Upper Piston Zinc Valve Piston Assembly Brass Polyurethane Springs Stainless Steel Seals Nitrile Solenoid Valve Valve Normally Closed 3 2 Way Seat Port Diameter 1 3 mm Max Ambient Temperature 82 C...

Страница 6: ...Valve Body Refer to Dwg 45534054 and Parts List Disconnect the pilot regulator assembly from the cap 1 of the valve Using a strap wrench unscrew and remove the housing cover 2 Pull the return spring...

Страница 7: ...50 5P Valve Tune Up Kit Includes Items 4 5 6 7 8 9 RR100 TK1 3 Parts and Maintenance CAUTION The use of other than genuine Ingersoll Rand replacement parts may result in safety hazards decreased motor...

Страница 8: ...www irtools com 2007 Ingersoll Rand Company...

Отзывы: