Operator settings folder
Pages 1-2: Operator Settings
Figure 35: Operator Settings
Table 14: Operator Settings
Operator
Settings
Selection Min . Max .
Default
Step
Unit
Offline
Pressure
---
75
Rated+10 Rated+10
1
psi
Online
Pressure
---
65
Offline-10 Offline-10
1
psi
Lead/Lag
Lead/Lag
---
---
Lead
---
---
Lag Offset
---
0
45
0
1
psi
Mode of
Operation
Mode
---
---
On/off line
---
---
Condensate
Release
---
2
20
5
1
sec
Condensate
Interval
---
90
270
180
1
sec
Stop Delay
Time
---
10
0
10
1
sec
Star-Delta
Time / Start
Time
---
5
0
10
1
sec
Pages 3-5: Operator Options
Figure 36: Operator Options
Table 15: Operator Options
Operator Options
Selection
Min .
Max .
Def .
Step
Unit
Installed option
required?
Enable Auto Restart
ON/OFF
---
---
Off
---
---
No
Auto Restart Time
---
2
60
10
1
min
No
Auto Restart Delay
---
0
60
0
1
sec
No
Comm Control
ON/OFF
---
---
Off
---
---
No
Remote Start/Stop
ON/OFF
---
---
Off
---
---
No
Power Out Restart
ON/OFF
---
---
Off
---
---
Yes
Power Out Restart Time
---
10
600
10
1
sec
Yes
Low Ambient Temp*
---
0
60
5
1
degF
No
Lead/Lag Cycle Time**
---
0
750
0
1
hours
No
Scheduled Start - Day
---
Day
Day
Sun
1
day
Yes
Scheduled Start
---
00:00
2:59
00:00
1
time
Yes
Scheduled Stop - Day
---
Day
Day
Sun
1
day
Yes
Scheduled Stop
---
00:00
2:59
00:00
1
time
Yes
High Dust Filter
ON/OFF
---
---
Off
---
---
Yes
Remote Sensor
ON/OFF
---
---
Off
---
---
Yes
* The low ambient temperature is only adjustable if the low ambient factory set point is on.
** A value of 0 will disable the lead/lag cycle time feature.