1.6.2 Assembly of the Male Docking Valve  

 
 

 

 
 
 

This operation requires, the following special tools and preparations: 

 

A T2000-17-005 to compress the spring (two threaded rods and a 
bracket with three holes). 

 

A flat, 7mm, fork spanner. 

 

Screw locking liquid - Loctite 270 

 

Special high temperature grease for the sealings, Uniway LIX 625. 

 

Torque wrench 

 

Two M6x35 screws 

 
a)  First place the valve needle complete (7) into the middle housing (1), together with the O-ring (17), 

coated with a little grease, into its groove, and attach the retaining flange (6) with the four 
countersunk screws (20). Tighten the screws crosswise, carefully and equal. 

b)  Insert the Stepseal® (16) in the immersion of the packing housing (2) and mount the retaining shim 

(5) with the two countersunk screws (22). Check the orientation of the Stepseal (16). The step 
must face the needle (see drawing).  

c)  Insert the Variseal (15) in the recess of middle housing (1) with the V-opening first (see drawing).  

Note:

 Be 

careful not to harm the sensitive edge of the seal. 

d)  Put the packing housing (2) onto the middle housing (1) and keep them fixed with the two M6x35 

screws mounted diagonally – temporarily. 

e)  Push the valve needle complete (7) in through the two seals (15) and (16) until the needle head 

touches the valve seat (closed valve).  

Note:

 

One will feel a certain resistance each time the needle enters a seal. 

 

f)  The O-ring (18), lightly greased, is put onto the piston (4). The distance shim (23 and 24) is “glued“ 

with grease on the bottom surface of the piston (4). This shim prevents the sharp end of the spring 
from wearing out the piston as the spring always turns a little when being compressed. 

g)  Mount the lightly greased spring (14) on top of the retaining shim (5). 

h)  The piston (4) is put into the spring (14). 

i)  Install the special (T2000-17-005-IR) tool into the two diagonally remaining holes of the middle 

housing (1), for compressing the spring. The spring is compressed by spanning it until the threaded 
part of the “valve needle complete” (7) reaches through the piston (4). 

j)  The seal lock nut (11) is screwed onto the thread with a torque wrench. 

Note: 

Always use a new 

nut, and always use screw-locking-liquid (Loctite 270). Keep the needle fixed with the 7mm-
spanner, and tighten the nut to the torque 5 Nm. 

k)  The special tool and the two temporarily fitted M6 screws can now be removed because the spring 

tension keeps the whole assembly together. 

l)  The inner surface of the air cylinder (3) must be greased carefully with Uniway LIX 625. 

Содержание DOSER

Страница 1: ...45532694 Edition 2 August 2007 Doser Docking Station Maintenance Manual...

Страница 2: ...1 3 Change Male Docking Valve Complete 5 1 4 Hydraulics of the Docking Station 6 1 5 Pneumatics of the Docking Station 7 1 6 Male Docking Valve 8 1 6 1 Dismantling of the Male Docking Valve 8 1 6 2 As...

Страница 3: ...IR Docking unit T2X 16 502 IR 503 IR a Turn of the pneumatic system ensuring the clamps are off The clamp is normally open when the doser is away from the docking station Upper position inside the gui...

Страница 4: ...ur screws 15 on T2X 16 502 IR 503 IR and remove the pneumatic clamp 10 on T2X 16 502 IR 503 IR Mount the new clamp The two alignment pins 16 are used for guidance and the eight hexagonal screws 15 on...

Страница 5: ...e valve complete 5 on T2X 16 502 503 from the docking unit Disconnect the air hose lubrication hoses and the electric connection Now the complete valve can be replaced Note To do maintenance work on t...

Страница 6: ...16 502 IR Docking Unit Onboard lub T2X 16 503 IR For doser hydraulics and pneumatics See Doser Maintenance Manual Form 45532660 NOTE Only lubrication of inlet valve for OnBoard Lubricetion No connecti...

Страница 7: ...ation T2X 16 501 IR Docking Unit ATC T2X 16 502 IR Docking Unit Onboard lub T2X 16 503 IR Also see pneumatic scheme T2X 07 xxx From To 1 Inlet pneumatics 2 Pneumatic valves connection 1 3 Pneumatic va...

Страница 8: ...lose the distance shims 23 and 24 e The packing housing 2 can now be removed Also the Variseal 15 can be removed f To take out the Step seal 16 the retaining shim 5 has to be removed by unscrewing th...

Страница 9: ...emporarily e Push the valve needle complete 7 in through the two seals 15 and 16 until the needle head touches the valve seat closed valve Note One will feel a certain resistance each time the needle...

Страница 10: ...ing n Position all parts on the docking valve according to the drawing Tighten the four screws 19 Torque is 10 Nm o Finally the pneumatic unit function should be tested Connect the air and check the m...

Страница 11: ...2X 20 029 IR sheet 505 7 BK 15 BN 33 BU 24 WH 6 XP61 36POL T2X SF 008 IR T2X 20 029 IR sheet 505 7 Length 270mm WH 3 XP62 19 POLES T2X SF 005 IR T2X 20 029 IR sheet 508 1 WH 3 XP61 36POL T2X SF 008 IR...

Страница 12: ...12 45532694_ed2 www irtools com 2007 Ingersoll Rand Company...