2.0 INTRODUCTION
Ingersoll Rand refrigerated air dryer removes moisture,
oil vapor, and other contaminants from compressed air.
These contaminants are detrimental to pneumatically
operated appliances, controls, instruments, machinery and
tools. This removal is accomplished by cooling the air with
a refrigeration unit to a temperature at which moisture in
the air is condensed and separated from the air stream. The
temperature the air is cooled to, normally between 36 and
40°F (1° and 3°C), is known as dew point. This dryer can be
easily installed into various pneumatic systems in which
dry air is required or desired. Please refer to Principles of
Operation for complete operating details.
3.0 WaRRaNTY
The Company warrants that the equipment manufactured by
it and delivered hereunder will be free of defects in material
and workmanship for a period of twelve months from the
date of placing the Equipment in operation or eighteen
months from the date of shipment from the factory,
whichever shall first occur. The Purchaser shall be obligated
to promptly report any failure to conform to this warranty,
in writing to the Company in said period, whereupon the
Company shall, at its option, correct such nonconformity, by
suitable repair to such equipment or, furnish a replacement
part F.O.B. point of shipment, provided the Purchaser has
stored, installed, maintained and operated such Equipment
in accordance with good industry practices and has
complied with specific recommendations of the Company.
Accessories or equipment furnished by the Company, but
manufactured by others, shall carry whatever warranty the
manufacturers have conveyed to the Company and which
can be passed on to the Purchaser. The Company shall not
be liable for any repairs, replacements, or adjustments to the
Equipment or any costs of labor performed by the Purchaser
or others without Company’s prior written approval.
The effects of corrosion, erosion and normal wear and tear
are specifically excluded. Performance warranties are limited
to those specifically stated within the Company’s proposal.
Unless responsibility for meeting such performance
warranties are limited to specified tests, the Company’s
obligation shall be to correct in the manner and for the
period of time provided above.
THE COMPANY MAKES NO OTHER WARRANTY OR
REPRESENTATION OF ANY KIND WHATSOEVER, EXPRESSED
OR IMPLIED, EXCEPT THAT OF TITLE, AND ALL IMPLIED
WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A
PARTICULAR PURPOSE, ARE HERBY DISCLAIMED.
Correction by the Company of nonconformities whether
patent or latent, in the manner and for the period of time
provided above, shall constitute fulfillment of all liabilities of
the Company for such nonconformities whether based on
contract, warranty negligence, indemnity, strict liability or
otherwise with respect to or arising out of such Equipment.
The Purchaser shall not operate Equipment which is
considered to be defective, without first notifying the
Company in writing of its intention to do so. Any such use of
Equipment will be at Purchaser’s sole risk and liability.
Note that this is Ingersoll Rand standard warranty. Any
warranty in force at the time of purchase of the equipment
or negotiated as part of the purchase order may take prec-
edence over this warranty.
4.0 REFRIgERaTED DRYER NOMENCLaTURE
DRYER
NOMINaL*
FLOW (Nm³/hr)
Ingersoll Rand
NON-CYCLINg
CONDENSER
TYPE
POWER
RaTINg
CONVERSION CHaRT
D
1700
2040
2720
3400
4080
IN
A = AIR
4 = 460-3-60
5 = 230-3-60
6 = 575-3-60
D = 380-3-60
0 = NEMA 1 1700 Nm³/hr = 1000 SCFM
2040 Nm³/hr = 1200 SCFM
2720 Nm³/hr = 1600 SCFM
3400 Nm³/hr = 2000 SCFM
4080 Nm³/hr = 2400 SCFM
* Nominal Flows indicated are for 100°F inlet temperature, 100°F ambient temperature and 100 psig compressed air pressure.
Содержание D1700IN
Страница 30: ......
Страница 31: ......
Страница 32: ...ingersollrandproducts com 2012 Ingersoll Rand Company ...