background image

OPERATOR’S MANUAL

PH10A-X-X

RELEASED:

7-7-00

REVISED:
(REV.

 

P

)

INCLUDING: OPERATION, INSTALLATION & SERVICE

1” HIGH PRESSURE DIAPHRAGM PUMP

3:1 RATIO (METALLIC)

READ THIS MANUAL CAREFULLY BEFORE INSTALLING,

OPERATING OR SERVICING THIS EQUIPMENT.

It is the responsibility of the employer to place this information in the hands of the operator. Keep for future reference.

SERVICE KITS

Refer to “Model Description Chart” to match the pump material options.
637338 for air section repair (see page 6).
637339 for fluid section repair (models PH10A-XXX-XSX)(see page 4).
637339-1 for fluid section repair (models PH10A-XXX-XHX)(see page 4).

PUMP DATA

Models

see “Model Description Chart” for “-XXX”.

. . . . . . . . . . .

Pump Type

Metallic Air Operated, High Pressure,

. . . . . . . .

Double Diaphragm.

Material

see “Model Description Chart”.

. . . . . . . . . . .

Weight

94.73 lbs (42.97 kg)

. . . . . . . . . . . . . . . . . . . . . . . . .

Maximum Air Inlet Pressure

100 psig (6.9 bar)

. . . . . . . . .

Maximum Outlet Pressure

300 psig (20.4 bar)

. . . . . . . . . .

Maximum Flow Rate (flooded inlet)

26 gpm (98.4 lpm)

. . .

Maximum Particle Size

1/8” dia. (3.2 mm)

. . . . . . . . . . . .

Maximum Temperature Limits (diaphragm / ball / seal material)

Nitrile

10

_

to 180

_

F (-12

_

to 82

_

C)

. . . . . . . . . . . . . . . . .

PTFE

40

_

to 225

_

F (4

_

to 107

_

C)

. . . . . . . . . . . . . . . . .

Displacement / Cycle @ 100 psig

0.06 gal. (0.23 lit.)

. . . . .

Dimensional Data

see page 8.

. . . . . . . . . . . . . . . .

Noise Level @ 70 psig, 60 cpm

84.5 dB(A)

j

. . . . . .

j

The pump sound pressure levels published here have been updated to an Equivalent Continuous
Sound Level (L

Aeq

) to meet the intent of ANSI S1.13-1971, CAGI-PNEUROP S5.1 using four micro-

phone locations.

NOTICE: All possible options are shown in the chart. However, certain
combinations may not be recommended, consult a representative or the
factory if you have questions concerning availability.

PH10A-XSS-XXT

1” DIAPHRAGM PUMP

Figure 1

MODEL DESCRIPTION CHART

PH10 A - X S S - X X T

Seat Material

H - Hard 440 Stainless Steel
S - 316 Stainless Steel

Ball Material

H - Hard 440 Stainless Steel
S - 316 Stainless Steel

Fluid Caps & Manifold Material

S - Stainless Steel

Fluid Connection

A - 1 - 11-1/2 NPTF - 1
B - Rp 1 (1 - 11 BSP parallel)

Diaphragm Material

T -  PTFE

Hardware Material

S - Stainless Steel

Center Section Material

A - Aluminum

INGERSOLL RAND COMPANY LTD

209 NORTH MAIN STREET – BRYAN, OHIO 43506

(800) 495-0276

  

FAX(800) 892-6276

 

©

 

201

6

CCN

99755480

arozone.com

7-15-16

L -  Long Life PTFE

Содержание ARO PH10A Series

Страница 1: ...ture Limits diaphragm ball seal material Nitrile 10_ to 180_ F 12_ to 82_ C PTFE 40_ to 225_ F 4_ to 107_ C Displacement Cycle 100 psig 0 06 gal 0 23 lit Dimensional Data see page 8 Noise Level 70 psig 60 cpm 84 5 dB A j j The pump sound pressure levels published here have been updated to an Equivalent Continuous SoundLevel LAeq tomeet theintent of ANSI S1 13 1971 CAGI PNEUROP S5 1using four micro...

Страница 2: ...s tem by opening dispensing valve or device and or carefully and slowly loosening and removing outlet hose or piping from pump WARNING HAZARDOUS PRESSURE Can result in serious injury or property damage Do not service or clean pump hoses or dispensing valve while the system is pressurized WARNING HAZARDOUSMATERIALS Cancauseseriousin juryorpropertydamage Donotattempttoreturnapumptothe factory or ser...

Страница 3: ...th a solvent compatible with the material beingpumpedifthematerialbeing pumpedis subjectto settingup when not in use for a period of time S Disconnecttheairsupplyfromthepumpifitistobeinactiveforafew hours START UP 1 Turn pressure control knob until motor starts to cycle 2 Allow pump to cycleslowly untilit isprimed andall airis purgedfrom the fluid hose or dispensing valve 3 Turn off dispensing val...

Страница 4: ...er damage FLUID SECTION REASSEMBLY S Clean all parts upon reassembly Lubricate all replacement parts and metallic moving parts with Key Lube grease upon reassembly S SERVICE NOTE PTFE O rings are not resilient and they should always be replaced with new ones 1 Install the 164 back up ring by pulling it apart twist or walk it down into the cavity bottom inside the 163 bushing 2 Install the 165 quad...

Страница 5: ...ads at assembly l Apply Loctite 271 to threads at assembly m Apply anti sieze compound to threads and bolt and nut flange heads which contact pump case when using stainless steel fasteners ASSEMBLY NOTES n Assemble with i d chamfer against bolt head o Assemble with largest convolusion ripple towards 6 diaphragm plate Figure 2 FOR THE AIR MOTOR SECTION SEE PAGES 6 7 36 26 m 2 j 1 124 149 150 j 148 ...

Страница 6: ...DE A Aluminum C Carbon Steel SS Stainless Steel B Nitrile D Acetal T PTFE Br Brass Fg Fiberglas U Polyurethane Bz Bronze SH Hard Stainless Steel Z Zinc AIR SECTION SERVICE Service is divided into two parts 1 Pilot Valve 2 Major Valve GENERAL SERVICE NOTES S Air Motor Section Service is continued from step 8 of the Fluid Sec tion Disassembly S It is not necessary to remove the Fluid Section Ends to...

Страница 7: ...ide Clean and inspect all parts for damage and wear MAJOR VALVE REASSEMBLY S Lubricateallsoftparts spool andboreswithKey Lubegreaseupon reassembly 1 For best results rebuild the Major Valve stack one piece at a time Start with the 112 washer and install it in the side opposite the air inlet Place the washer into the bore with the raised edge facingout ward follow it with the larger 114 O ring 2 Pl...

Страница 8: ... sleeve and 2 O ring on 1 rod S Check 168 O rings on 167 pilot piston for wear Low output volume S Check air supply S Check for plugged outlet hose S For the pump to prime itself it must be mounted in the vertical posi tion so that the balls will check by gravity S Check for pump cavitation suction pipe should be 1 minimum or larger if high viscosity fluids are being pumped Suction hose must be no...

Отзывы: