Ingersoll-Rand ARO PE20-B0S Series Скачать руководство пользователя страница 2

CAUTION

NOTICE

WARNING

 EXCESSIVE AIR PRESSURE. Can cause per-

sonal injury, pump damage or property damage.

 

y

Do not exceed the maximum inlet air pressure as 

stated on the pump model plate.

 

y

Be sure material hoses and other components are 

able to withstand fluid pressures developed by this 

pump. Check all hoses for damage or wear. Be certain 

dispensing device is clean and in proper working con-

dition.

WARNING

 STATIC SPARK. Can cause explosion re-

sulting in severe injury or death. Ground pump and 

pumping system.

 

y

Use the pump grounding screw terminal provided. 

Use ARO part no. 66885-1 ground kit or connect a 

suitable ground wire (12 ga. min.) to a good earth 

ground source.

 

y

Secure pump, connections and all contact points to 

avoid vibration and generation of contact or static 

spark.

 

y

Consult local building codes and electrical codes for 

specific grounding requirements.

 

y

After grounding, periodically verify continuity of 

electrical path to ground. Test with an ohmmeter 

from each component (e.g., hoses, pump, clamps, con-

tainer, spray gun, etc.) to ground to insure continuity. 

Ohmmeter should show 0.1 ohms or less.

 

y

Submerse the outlet hose end, dispensing valve or 

device in the material being dispensed if possible. 

(Avoid free streaming of material being dispensed.)

 

y

Use hoses incorporating a static wire.

 

y

Use proper ventilation.

 

y

Keep inflammables away from heat, open flames and 

sparks.

 

y

Keep containers closed when not in use.

WARNING

 Pump exhaust may contain contami-

nants. Can cause severe injury. Pipe exhaust away 

from work area and personnel.

 

y

In the event of a diaphragm rupture, material can be 

forced out of the air exhaust muffler.

 

y

Pipe the exhaust to a safe remote location when 

pumping hazardous or inflammable materials.

 

y

Use a grounded 1” minimum i.d. hose between the 

pump and the muffler.

WARNING

 HAZARDOUS PRESSURE. Can result in 

serious injury or property damage. Do not service or 

clean pump, hoses or dispensing valve while the sys-

tem is pressurized.

 

y

Disconnect air supply line and relieve pressure from 

the system by opening dispensing valve or device and 

/ or carefully and slowly loosening and removing out-

let hose or piping from pump.

WARNING

 HAZARDOUS MATERIALS. Can cause 

serious injury or property damage. Do not attempt 

to return a pump to the factory or service center that 

contains hazardous material. Safe handling practices 

must comply with local and national laws and safety 

code requirements.

OPERATING AND SAFETY PRECAUTIONS

READ, UNDERSTAND AND FOLLOW THIS INFORMATION TO AVOID INJURY AND PROPERTY DAMAGE.

Page 2 of 8 

PE20X-X-X-B0S (en)

 

y

Obtain Material Safety Data Sheets on all materials 

from the supplier for proper handling instructions.

WARNING

 EXPLOSION HAZARD. Models containing 

aluminum wetted parts cannot be used with 1,1,1-tri-

chloroethane, methylene chloride or other haloge-

nated hydrocarbon solvents which may react and 

explode.

 

y

Check pump motor section, fluid caps, manifolds and 

all wetted parts to assure compatibility before using 

with solvents of this type.

WARNING

 MISAPPLICATION HAZARD. Do not use 

models containing aluminum wetted parts with food 

products for human consumption. Plated parts can 

contain trace amounts of lead.

    

           Verify the chemical compatibility of the 

pump wetted parts and the substance being pumped, 

flushed or recirculated. Chemical compatibility may 

change with temperature and concentration of the 

chemical(s) within the substances being pumped, 

flushed or circulated. For specific fluid compatibility, 

consult the chemical manufacturer.

CAUTION

 Maximum temperatures are based on 

mechanical stress only. Certain chemicals will signifi-

cantly reduce maximum safe operating temperature. 

Consult the chemical manufacturer for chemical com-

patibility and temperature limits. Refer to PUMP DATA 

on page 1 of this manual.

CAUTION

 Be certain all operators of this equipment 

have been trained for safe working practices, under-

stand it’s limitations, and wear safety goggles / equip-

ment when required.

                             Do not use the pump for the structural sup-

port of the piping system. Be certain the system com-

ponents are properly supported to prevent stress on 

the pump parts.

 

y

Suction and discharge connections should be flex-

ible connections (such as hose), not rigid piped, 

and should be compatible with the substance being 

pumped.

CAUTION

 Prevent unnecessary damage to the pump. 

Do not allow pump to operate when out of material 

for long periods of time.

 

y

Disconnect air line from pump when system sits idle 

for long periods of time.

CAUTION

 Use only genuine ARO replacement parts 

to assure compatible pressure rating and longest ser-

vice life.

                            Replacement warning labels are available 

upon request: “Static Spark & Diaphragm Rupture” pn 

\ 94080.

WARNING

 = Hazards or unsafe practices which 

could result in severe personal injury, 

death or substantial property damage.

 

= Hazards or unsafe practices which 

could result in minor personal injury, 

product or property damage.

 

    =  Important installation, operation or  

maintenance information.

EXCESSIVE AIR PRESSURE

STATIC SPARK

HAZARDOUS MATERIALS

HAZARDOUS PRESSURE

CAUTION

CAUTION

NOTICE

Содержание ARO PE20-B0S Series

Страница 1: ...Limits diaphragm ball seal material E P R EPDM 60 to 280 F 51 to 138 C Hytrel 20 to 180 F 29 to 82 C Nitrile 10 to 180 F 12 to 82 C Kynar PVDF 10 to 200 F 12 to 93 C Santoprene 40 to 225 F 40 to 107...

Страница 2: ...ents OPERATING AND SAFETY PRECAUTIONS READ UNDERSTAND AND FOLLOWTHIS INFORMATIONTO AVOID INJURY AND PROPERTY DAMAGE Page 2 of 8 PE20X X X B0S en y y Obtain Material Safety Data Sheets on all materials...

Страница 3: ...r models with PTFE diaphragms Item 8 Santoprene diaphragm is installed with the side marked AIR SIDE towards the pump center body Install the 7 PTFE dia phragm with the side marked FLUID SIDE towards...

Страница 4: ...p XSX 94805 4 SS CXX 94328 C 4 H KXX 94477 K 4 K XCX 93358 C 4 H XTX 93358 4 4 T EXX 95677 4 C LXX 95639 4 Ha XGX 93358 2 4 B XVX 93358 3 4 V FXX 95673 4 A SXX 94353 4 SS XMX 93358 M 4 MSp GXX 94328 G...

Страница 5: ...Not used with PE20X XXX AXX B0S CXX and GXX Lubriplate FML 2 is a white food grade petroleum grease PARTS LIST PE20X X X B0S FLUID SECTION PE20X X X B0S en Page 5 of 8 View for PE20X XXX XXT B0S PTFE...

Страница 6: ...Remove 121 plugs AIR MOTOR SECTION REASSEMBLY 1 Clean and lubricate parts not being replaced from service kit 2 Replace 173 O rings and assemble 121 plugs 3 Assemble 132 and 166 gaskets and 176 checks...

Страница 7: ...asket on models PE20S XXX XXX B0S 147 146 TORQUE REQUIREMENTS NOTE DO NOT OVERTIGHTEN FASTENERS ALL FASTENERS ARE METRIC 134 Screw 40 50 in lbs 4 5 5 6 Nm LUBRICATION SEALANTS Apply Lubriplate FML 2 g...

Страница 8: ...for reference only they are displayed in inches and millimeters mm Figure 4 PN 97999 1214 P DIMENSIONS A see below F 12 304 8 mm L see below R see below B 24 3 4 628 7 mm G 26 1 4 666 8 mm M 5 8 15 9...

Отзывы: