background image

Page 2 of 8 

66625X-XXX-C (en)

WARNING

 EXCESSIVE AIR PRESSURE. Can cause personal 

injury, pump damage or property damage.

y

Do not exceed the maximum inlet air pressure as stated on 

the pump model plate.

y

Be sure material hoses and other components are able to 

withstand fluid pressures developed by this pump. Check 

all hoses for damage or wear. Be certain dispensing device 

is clean and in proper working condition.

WARNING

 STATIC SPARK. Can cause explosion resulting in 

severe injury or death. Ground pump and pumping system.

 

y

Sparks can ignite flammable material and vapors.

 

y

The pumping system and object being sprayed must be 

grounded when it is pumping, flushing, recirculating or 

spraying flammable materials such as paints, solvents, 

lacquers, etc. or used in a location where surrounding atmo-

sphere is conducive to spontaneous combustion. Ground the

dispensing valve or device, containers, hoses and any object 

to which material is being pumped.

 

y

Use the pump grounding screw terminal provided. Use ARO®

part no. 66885-1 ground kit or connect a suitable ground 

wire (12 ga. minimum) to a good earth ground source.

y

Secure pump, connections and all contact points to avoid 

vibration and generation of contact or static spark.

y

Consult local building codes and electrical codes for specif-

ic grounding requirements.

y

After grounding, periodically verify continuity of electrical 

path to ground. Test with an ohmmeter from each compo-

nent (e.g., hoses, pump, clamps, container, spray gun, etc.) 

to ground to insure continuity. Ohmmeter should show 0.1 

ohms or less.

y

Submerse the outlet hose end, dispensing valve or device 

in the material being dispensed if possible. (Avoid free 

streaming of material being dispensed.)

y

Use hoses incorporating a static wire.

y

Use proper ventilation.

y

Keep inflammables away from heat, open flames and 

sparks.

y

Keep containers closed when not in use.

WARNING

 Pump exhaust may contain contaminants. Can 

cause severe injury. Pipe exhaust away from work area and 

personnel.

y

In the event of a diaphragm rupture, material can be forced 

out of the air exhaust muffler.

y

Pipe the exhaust to a safe remote location when pumping 

hazardous or inflammable materials.

y

Use a grounded 3/4” minimum ID hose between the pump 

and the muffler.

WARNING

 HAZARDOUS PRESSURE. Can result in serious 

injury or property damage. Do not service or clean pump, 

hoses or dispensing valve while the system is pressurized.

y

Disconnect air supply line and relieve pressure from the 

system by opening dispensing valve or device and / or 

carefully and slowly loosening and removing outlet hose 

or piping from pump.

WARNING

 HAZARDOUS MATERIALS. Can cause serious in-

jury or property damage. Do not attempt to return a pump 

to the factory or service center that contains hazardous 

material. Safe handling practices must comply with local 

and national laws and safety code requirements.

OPERATING AND SAFETY PRECAUTIONS

READ, UNDERSTAND AND FOLLOW THIS INFORMATION TO AVOID INJURY AND PROPERTY DAMAGE.

y

Obtain Material Safety Data Sheets on all materials from 

the supplier for proper handling instructions.

WARNING

 EXPLOSION HAZARD. Models containing alu-

minum parts cannot be used with 1,1,1-trichloroethane, 

methylene chloride or other halogenated hydrocarbon 

solvents which may react and explode.

y

Check pump motor section, fluid caps, manifolds and all 

wetted parts to assure compatibility before using with 

solvents of this type.

WARNING

 MISAPPLICATION HAZARD. Do not use models 

containing aluminum wetted parts with food products 

for human consumption. Plated parts can contain trace 

amounts of lead.

CAUTION

 Verify the chemical compatibility of the pump 

wetted parts and the substance being pumped, flushed 

or recirculated. Chemical compatibility may change with 

temperature and concentration of the chemical(s) within 

the substances being pumped, flushed or circulated. For 

specific fluid compatibility, consult the chemical manufac-

turer.

CAUTION

 Maximum temperatures are based on mechan-

ical stress only. Certain chemicals will significantly reduce 

maximum safe operating temperature. Consult the chemi-

cal manufacturer for chemical compatibility and tempera-

ture limits. Refer to PUMP DATA on page 1 of this manual.

CAUTION

 Be certain all operators of this equipment have 

been trained for safe working practices, understand it’s 

limitations, and wear safety goggles / equipment when 

required.

CAUTION

 Do not use the pump for the structural support 

of the piping system. Be certain the system components 

are properly supported to prevent stress on the pump 

parts.

y

Suction and discharge connections should be flexible 

connections (such as hose), not rigid piped, and should be 

compatible with the substance being pumped.

CAUTION

 Prevent unnecessary damage to the pump. Do 

not allow pump to operate when out of material for long 

periods of time.

y

Disconnect air line from pump when system sits idle for 

long periods of time.

CAUTION

 Use only genuine ARO replacement parts to 

assure compatible pressure rating and longest service life.

NOTICE

 Replacement warning labels are available upon 

request: “Static Spark (93616-1) & Diaphragm Rupture” 

(93122).

WARNING

  = Hazards or unsafe practices which 

could result in severe personal injury, 

death or substantial property damage.

CAUTION

  = Hazards or unsafe practices which 

could result in minor personal injury, 

product or property damage.

NOTICE

= Important installation, operation or 

maintenance  information.

EXCESSIVE AIR PRESSURE 

STATIC SPARK

HAZARDOUS MATERIALS

HAZARDOUS PRESSURE

Содержание ARO 66625 C Series

Страница 1: ...4 dia 6 4 mm Maximum Temperature Limits diaphragm ball seal seat material E P R EPDM 60 to 280 F 51 to 138 C Hytrel 20 to 180 F 29 to 82 C Kynar PVDF 10 to 200 F 12 to 93 C Nitrile 10 to 180 F 12 to 8...

Страница 2: ...attempt to return a pump to the factory or service center that contains hazardous material Safe handling practices must comply with local and national laws and safety code requirements OPERATING AND...

Страница 3: ...ARO diaphragm pump offers high volume delivery even at low air pressure and a broad range of material compatibility options are available Refer to the model and option chart ARO pumps feature stall re...

Страница 4: ...hragm XX Ball XX Diaphragm Diaphragm Qty Mtl Diaphragm Qty Mtl O Ring Qty Mtl XX2 637432 XX2 637432 X2 97284 2 2 B Y325 237 4 B XX4 637432 XX4 637432 X4 96392 T 2 T 96393 A 2 Sp Y328 237 4 T XX6 48497...

Страница 5: ...y anti seize compound to threads and bolt and nut ange heads which contact pump case when using stain less steel fasteners Not used with models 6662XX 9XX C 6662XX EXX C and 6662XX GXX C FORTHE AIR MO...

Страница 6: ...onto 115 spacer and insert etc NOTE Be careful to orient spacer legs away from blocking internal ports 2 Lubricate and carefully insert 111 spool 3 Install 117 gasket and 107 plate 4 Lubricate and ins...

Страница 7: ...NOT OVERTIGHTEN FASTENERS 105 screw 40 50 in lbs 4 5 5 6 Nm 123 screw 20 25 in lbs 2 3 2 8 Nm LUBRICATION SEALANTS Apply Key Lube grease to all O rings U cups and mating parts Apply Loctite 271 to thr...

Страница 8: ...the pump for solid objects lodged in the diaphragm chamber or the seat area DIMENSIONAL DATA A E G M L F N B H J D K C P S Exhaust port Q Material inlet Q Material outlet R Air inlet Dimensions shown...