INSTALLATION

Position the two (14) mounting plates on the two post lift 
mounting arm (see fi gures 2 and 3).
Using four (16) cap screws and four (13) lock washers, fasten 
the mounting plates to the four holes located on the top of the 
mounting arm.
Place the air manifold assembly on the mounting plates and 
secure using two (11) "U" bolts, four (13) lock washers and four 

1.

2.

3.

(12) nuts (see fi gures 1 and 2).

NOTE: The regulator is rotated upward 90° for easier viewing of (5) 
gauge.
4.  Connect the (9) hose and (10) swivel to the pump air motor 

inlet.

5.  Connect 1/2" i.d. air line hose to (3) fi lter.