Ingersoll-Rand ARO 650936-XX3 Series Скачать руководство пользователя страница 2

650936-X

PUMP OPTION DESCRIPTION CHART

650936

ā

ā

X

PACKING MATERIAL

PLUNGER TYPE

SPRINGARRANGEMENT

PACKING MATERIAL

(PACKINGS ARE UPPER AND LOWER UNLESS NOTED)

3

GLASS FILLED

P

STAG'D (UPPER)

C

UHMW-PE

UHMW-PE (LOWER)

G

UHMW-PE/LEATHER STAG'D

R

SPRING ARRANGEMENT

1

COIL SPRING

4

MULTIPLE WAVE SPRING

PLUNGER TYPE

3

HD SS W/HD CHROME PLATING

X 3

GENERAL DESCRIPTION

 WARNING

HAZARDOUS PRESSURE. Do not exceed maxiĆ

mum operating pressure of 1472 psi (102 bar) at 1200 psi (83

bar) inlet hydraulic pressure.

PUMP RATIO X

MAXIMUMPUMP

INLET PRESSURE TO PUMP MOTOR

=

FLUIDPRESSURE

Pump ratio is an expression of the relationship between the pump motor area and the

lower pump end area. EXAMPLE: When 150 p.s.i. (10.3 bar) inlet pressure is supplied

to the motor of a 5:1 ratio pump it will develop a maximum of 750 p.s.i. (52 bar) fluid

pressure (at no flow) - as the fluid control is opened, the flow rate will increase as the

motor cycle rate increases to keep up with the demand.

 WARNING

Refer to general information sheet for additional

safety precautions and important information.

The Two-Ball pumps are primarily designed for the pumping of meĆ

dium viscosity fluids compatible with carbon steel. The lower pump

is designed for easy priming and the double acting feature is stanĆ

dard in all ARO industrial pumps. Material is delivered to the pump

discharge outlet on both the up and down stroke.

The motor is connected to the lower pump end by a spacer section.

This allows for lubrication of the upper packing gland and prevents

motor contamination because of normal wear and eventual leakĆ

age through the material packing gland. Be sure the solvent cup is

adequately filled with lubricant to protect the upper packings and

insure longest service life.

TROUBLE SHOOTING

Pump problems can occur in either the Hydraulic Motor Section or the

Lower Pump End Section, use these basic guidelines to help determine

which section is affected.

If the pump will not cycle.

Be certain to first check for non-pump problems including kinked,

restrictive or plugged inlet/outlet hose or dispensing device. DeĆ

pressurize the pump system and clean out any obstructions in the

inlet/outlet material lines.

Refer to the motor manual for trouble shooting if the pump does not

cycle and/or hydraulic fluid leaks from the hydraulic motor.

If the pump cycles but does not deliver material.

Refer to the lower pump end manual for further trouble shooting.

PUMP CONNECTION – UPPER / LOWER

NOTE: All threads are right hand.

1. Lay the pump assembly on a workbench.

2. Remove the top three screws and washers from the three spacer

rods (see figure 1).

3. Pull the hydraulic motor from the lower pump end until motor piston

rod is in the ``down" position and lower pump end rod is in ``up" posiĆ

tion.

4. Remove the three spacer rods by unscrewing the bottom three cap

screws and washers.

5. Remove the cotter pin and unscrew the lower pump end rod from

the adapter (see figure 2).

Pump Motor

Piston Rod

Cotter Pin

Y15–47–C

Adapter

93350–1

PUMP CONNECTOR DETAIL

FIGURE 2

REASSEMBLY

1. Align the pump motor with the lower pump end.

2. Screw the adapter onto the motor piston rod.

3. Screw the lower pump rod into the adapter and secure with the cotĆ

ter pin. NOTE: Bend the ends of the pin into the groove of adapter.

4. Reinstall the spacer rods to the lower pump end, securing with

three washers and cap screws.

5. Bring the motor and lower pump together and retain with the three

screws and washers.

PN 97999-546

6).81&15'&

15'&6).81&45"(h% 611&3

15'& -08&3

15'&

Отзывы: