Ingersoll-Rand ARO 637140-4B Скачать руководство пользователя страница 3

670093 (en) 

Page 3 of 12

GENERAL DESCRIPTION

The ARO diaphragm pump offers high volume delivery even 

at low air pressure and a broad range of material compatibility 

options available. Refer to the model and option chart. ARO 

pumps feature stall resistant design, modular air motor / fluid 

sections. 

Air operated double diaphragm pumps utilize a pressure dif-

ferential in the air chambers to alternately create suction and 

positive fluid pressure in the fluid chambers, ball checks insure 

a positive flow of fluid. 

Pump cycling will begin as air pressure is applied and it will 

continue to pump and keep up with the demand. It will build 

and maintain line pressure and will stop cycling once maxi-

mum line pressure is reached (dispensing device closed) and 

will resume pumping as needed.

AIR AND LUBE REQUIREMENTS

WARNING

 

EXCESSIVE AIR PRESSURE. Can cause pump 

damage, personal injury or property damage.

 

y

A filter capable of filtering out particles larger than 50 

microns should be used on the air supply. There is no lu-

brication required other than the “O” ring lubricant which is 

applied during assembly or repair.

 

y

If lubricated air is present, make sure that it is compatible 

with the “O” rings and seals in the air motor section of 

the pump.

OPERATING INSTRUCTIONS

 

y

Always flush the pump with a solvent compatible with the 

material being pumped if the material being pumped is 

subject to setting up” when not in use for a period of time.

 

y

Disconnect the air supply from the pump if it is to be inactive 

for a few hours.

 

y

The outlet material volume is governed not only by the air 

supply but also by the material supply available at the inlet. 

The material supply tubing should not be too small or restric-

tive. Be sure not to use hose which might collapse.

 

y

When the diaphragm pump is used in a forced-feed (flooded 

inlet) situation, it is recommended that a “Check Valve” be 

installed at the air inlet.

 

y

Secure the diaphragm pump legs to a suitable surface to 

insure against damage by vibration.

MAINTENANCE

Provide a clean work surface to protect sensitive internal 

moving parts from contamination from dirt and foreign mat-

ter during service disassembly and reassembly.

 

y

Certain ARO “Smart Parts” are indicated which should be 

available for fast repair and reduction of down time.

 

y

Service kits are available to service two separate dia-

phragm pump functions: 1. AIR SECTION, 2. FLUID SEC-

TION. The Fluid Section is divided further to match typical 

active MATERIAL OPTIONS.

 

y

Provide a clean work surface to protect sensitive internal 

moving parts from contamination from dirt and foreign 

matter during service disassembly and reassembly.

 

y

Keep good records of service activity and include pump 

in preventive maintenance program.

 Viton

®

, and Hytrel

®

 are registered trademarks of the DuPont

®

  Company  Loctite

®

 is a registered trademark of Henkel Loctite Corporation 

  Santoprene

®

 is a registered trademark of Monsanto Company, licensed to Advanced Elastomer Systems, L.P.  Lubriplate

®

 is a registered trademark of Lubriplate Division (Fiske Brothers Refining Company)   

Содержание ARO 637140-4B

Страница 1: ...del 670093 670109 PumpType Non Metallic Air Operated Double Diaphragm Material see Model Description Chart Weight Polypropylene 7 2 3 3 kgs Maximum Air Inlet Pressure 100 psig 6 9 bar Maximum Material...

Страница 2: ...ing out let hose or piping from pump WARNING HAZARDOUS MATERIALS Can cause serious injury or property damage Do not attempt to return a pump to the factory or service center that contains hazardous ma...

Страница 3: ...d of time y Disconnect the air supply from the pump if it is to be inactive for a few hours y The outlet material volume is governed not only by the air supply but also by the material supply availabl...

Страница 4: ...4 93100 4 T 26 Bolt 5 16 16 x 1 1 2 16 93109 SS 29 Set Screw for model 670093 2 Y29 132 S SS for model 670109 33 O Ring 1 3 16 OD 4 93762 E 34 Manifold Outlet top 2 93102 1 P 35 Manifold Foot bottom 2...

Страница 5: ...NTS NOTE DO NOT OVERTIGHTEN FASTENERS 6 Diaphragm nut 95 105 in lbs 10 7 11 9 Nm 62 Fluid cap manifold nuts 50 60 in lbs 5 6 6 8 Nm alternately and evenly then re torque after initial run in 39 Nuts 2...

Страница 6: ...UID SECTION DISASSEMBLY 1 Remove 34 top manifold 36 swivel assembly 2 Remove 19 O rings 21 seats and 22 balls 3 Remove 35 bottom manifolds 36 swivel assembly 4 Remove 19 O rings 21 seats and 22 balls...

Страница 7: ...ly Lubriplate 94276 to all O rings U cups and mating parts 135 174 134 144 Position Sensor when pump is completely assembled Screw Sensor 233 into Exhaust Cover 129 until it contacts Ring 2 Backout 1...

Страница 8: ...al position so that the balls will check by gravity y Check for pump cavitation suction pipe should be sized at least as large as the inlet thread diameter of the pump for proper flow if high viscosit...

Страница 9: ...stem Valve will not run when pump does not cycle Supply air Air pilot return solenoid actuated 4 way valve PLC Controller signal Pneumatic feedback signal from pump TYPICAL BASIC REMOTE HOOK UP 10 32...

Страница 10: ...nal from pump Pneumaticecho can be used to interrupt the PLC signal and set alarm NOTE Pump may not be short stroked with this system Pneumatic to electric signal can send alarm to operating system LE...

Страница 11: ...670093 en Page 11 of 12 NOTES...

Страница 12: ...Page 12 of 12 670093 en PN 97999 1471...