Some models are provided with a menu through which the user can select the main measurement unit, Quarts (

Qts

), Pints (

Pts

), Litres (

Lit

), 

Gallons (

Gal

);

The combination of the unit of measurement of the Partial register and that of the Totals is prede

fi 

 ned according to the following table:

Combination 

no.

  

Unit of Measurement

Partial Register

Unit of Measurement

Totals Register

1

Litres  (L)

Litres (L)

2

Gallons (Gal)

Gallons  (Gal)

3

Quarts (Qts)

Gallons 

(Gal)

4

Pints (Pts)

Gallons 

(Gal)

To choose between the 4 available combinations:

Wait for the METER to go to Standby  

 

 

  

 

Then press the CAL and RESET keys together. Keep these pressed until the word “UNIT” 

a

ppears on the screen

 together with the unit of measurement set at that time 

(in this example Litres / Litres ) 

Every short press of the RESET key, the various combinations of 

 

the units of measurements 

are scrolled as shown below:

By pressing the CAL key at length, the new settings will be stored, the METER will pass through the start cycle and will then be ready to dispense 

in the set units.

NO new calibration is required after changing the Unit of Measurement.

M

EA

SUREMENT UNITS CONFIGURATION

FOR 635190-X DIGITAL METER

IMPORTANT

The Reset Total and Total regist

er

s will be automatically changed to the new unit of

 measurement.

PAGE 

3

 0F 8