Safety Precautions
14
If the victim must be removed from a live circuit,
pull the victim off with a non-conductive material.
Use the victim’s coat, a rope, wood, or loop your
belt around the victim’s leg or arm and pull the
victim off.
Do not touch
the victim. You can
receive a shock from current flowing through the
victim’s body. After separating the victim from
the power source, check immediately for the
presence of a pulse and respiration. If a pulse is
not present, start CPR (Cardiopulmonary
Resuscitation) and call for emergency medical
assistance. If a pulse is present, respiration may be
restored by using mouth-to-mouth resuscitation,
but call for emergency medical assistance.
Low Voltage
Control circuits used in the temperature control
unit are low voltage (12 and 24 Vdc). This voltage
potential is not considered dangerous, but the
large amount of current available (over 30 amps)
can cause severe burns if shorted or ground.
Do not wear jewelry, watch or rings when
working on the unit. If these items contact an
electrical circuit, severe burns may result.
Battery Installation and Cable
Routing
WARNING: Improperly installed battery
could result in a fire or explosion! A
Thermo King approved battery must be
installed and properly secured to the
battery tray.
WARNING: Improperly installed battery
cables could result in fire or explosion!
Battery cables must be installed, routed
and secured properly to prevent them from
rubbing, chaffing or making contact with
hot, sharp or rotating components.
WARNING: Do not attach fuel lines or
any additional wiring harnesses to the
battery cables as this could cause an
electrical fire!
CAUTION: Do not connect other
manufacturer’s equipment or accessories
to the Thermo King unit. This could result
in severe damage to equipment and void
the warranty!
CAUTION: Set all unit electrical controls
to the OFF position before connecting
battery cables to the battery to prevent unit
from starting unexpectedly and causing
personal injury.
CAUTION: Always wear protective
clothing, gloves and eye wear when
handling and installing batteries. Battery
acid can cause serious burns when
exposed to eyes or skin. If battery acid
contacts skin or clothing, wash
immediately with soap and water. If acid
enters your eye, immediately flood it with
running cold water for at least twenty
minutes and get medical attention
immediately.
CAUTION: Always cover battery
terminals to prevent them from making
contact with metal components during
battery installation. Battery terminals
grounding against metal could cause the
battery to explode.
Содержание 900829
Страница 2: ......
Страница 91: ...89 V 520 10 30 V 520 MAX 10 30 Wiring Diagram page 1 of 2 Thermo King RELEASED 26 Mar 2014...
Страница 92: ...90 V 520 10 30 V 520 MAX 10 30 Wiring Diagram page 2 of 2 RELEASED 26 Mar 2014...
Страница 93: ...91 V 520 10 30 V 520 MAX 10 30 Schematic Diagram page 1 of 2 Thermo King RELEASED 26 Mar 2014...
Страница 94: ...92 V 520 10 30 V 520 MAX 10 30 Schematic Diagram page 2 of 2 Thermo King RELEASED 26 Mar 2014...
Страница 95: ...93 V 520 20 50 1PH V 520 MAX 20 50 1PH Wiring Diagram page 1 of 3 Thermo King RELEASED 26 Mar 2014...
Страница 96: ...94 V 520 20 50 1PH V 520 MAX 20 50 1PH Wiring Diagram page 2 of 3 RELEASED 26 Mar 2014...
Страница 97: ...95 V 520 20 50 1PH V 520 MAX 20 50 1PH Wiring Diagram page 3 of 3 Thermo King RELEASED 26 Mar 2014...
Страница 98: ...96 V 520 20 50 1PH V 520 MAX 20 50 1PH Schematic Diagram page 1 of 3 RELEASED 26 Mar 2014...
Страница 99: ...97 V 520 20 50 1PH V 520 MAX 20 50 1PH Schematic Diagram page 2 of 3 RELEASED 26 Mar 2014...
Страница 100: ...98 V 520 20 50 1PH V 520 MAX 20 50 1PH Schematic Diagram page 3 of 3 RELEASED 26 Mar 2014...
Страница 101: ...99 V 520 20 50 3PH V 520 MAX 20 50 3PH Wiring Diagram page 1 of 3 Thermo King RELEASED 26 Mar 2014...
Страница 102: ...100 V 520 20 50 3PH V 520 MAX 20 50 3PH Wiring Diagram page 2 of 3 RELEASED 26 Mar 2014...
Страница 103: ...101 V 520 20 50 3PH V 520 MAX 20 50 3PH Wiring Diagram page 3 of 3 Thermo King RELEASED 26 Mar 2014...
Страница 104: ...102 V 520 20 50 3PH V 520 MAX 20 50 3PH Schematic Diagram page 1 of 3 RELEASED 26 Mar 2014...
Страница 105: ...103 V 520 20 50 3PH V 520 MAX 20 50 3PH Schematic Diagram page 2 of 3 RELEASED 26 Mar 2014...
Страница 106: ...104 V 520 20 50 3PH V 520 MAX 20 50 3PH Schematic Diagram page 3 of 3 RELEASED 26 Mar 2014...
Страница 107: ...105 V 520 MAX 10 SPECTRUM Wiring Diagram...
Страница 108: ...106 V 520 MAX 10 SPECTRUM Schematic Diagram page 1 of 2 2A 2A...
Страница 109: ...107 V 520 MAX 10 SPECTRUM Schematic Diagram page 2 of 2 2A 2A...
Страница 110: ...108 V 520 MAX 20 SPECTRUM 1PH Wiring Diagram page 1 of 3...
Страница 111: ...109 V 520 MAX 20 SPECTRUM 1PH Wiring Diagram page 2 of 3...
Страница 112: ...110 V 520 MAX 20 SPECTRUM 1PH Wiring Diagram page 3 of 3...
Страница 113: ...111 V 520 MAX 20 SPECTRUM 1PH Schematic Diagram page 1 of 3...
Страница 114: ...112 V 520 MAX 20 SPECTRUM 1PH Schematic Diagram page 2 of 3...
Страница 115: ...113 V 520 MAX 20 SPECTRUM 1PH Schematic Diagram page 3 of 3...
Страница 116: ...114 V 520 MAX 20 SPECTRUM 3PH Wiring Diagram page 1 of 3...
Страница 117: ...115 V 520 MAX 20 SPECTRUM 3PH Wiring Diagram page 2 of 3...
Страница 118: ...116 V 520 MAX 20 SPECTRUM 3PH Wiring Diagram page 3 of 3...
Страница 119: ...117 V 520 MAX 20 SPECTRUM 3PH Schematic Diagram page 1 of 3...
Страница 120: ...118 V 520 MAX 20 SPECTRUM 3PH Schematic Diagram page 2 of 3...
Страница 121: ...119 V 520 MAX 20 SPECTRUM 3PH Schematic Diagram page 3 of 3...
Страница 122: ...120 V 520 MAX 20 SPECTRUM 3PH 50 60 Hz Wiring Diagram page 1 of 2...
Страница 123: ...121 V 520 MAX 20 SPECTRUM 3PH 50 60 Hz Wiring Diagram page 2 of 2...
Страница 124: ...122 V 520 MAX 50 SPECTRUM 1PH Wiring Diagram page 1 of 2 Thermo King RELEASED 26 Mar 2014...
Страница 125: ...123 V 520 MAX 50 SPECTRUM 1PH Wiring Diagram page 2 of 2 Thermo King RELEASED 26 Mar 2014...
Страница 126: ...124 V 520 MAX 50 SPECTRUM 1PH Schematic Diagram page 1 of 3 RELEASED 26 Mar 2014...
Страница 127: ...125 V 520 MAX 50 SPECTRUM 1PH Schematic Diagram page 2 of 3 RELEASED 26 Mar 2014...
Страница 128: ...126 V 520 MAX 50 SPECTRUM 1PH Schematic Diagram page 3 of 3 RELEASED 26 Mar 2014...
Страница 129: ...127 V 520 MAX 50 SPECTRUM 3PH Wiring Diagram page 1 of 2 Thermo King RELEASED 26 Mar 2014...
Страница 130: ...128 V 520 MAX 50 SPECTRUM 3PH Wiring Diagram page 2 of 2 Thermo King RELEASED 26 Mar 2014...
Страница 131: ...129 V 520 MAX 50 SPECTRUM 3PH Schematic Diagram page 1 of 3 RELEASED 26 Mar 2014...
Страница 132: ...130 V 520 MAX 50 SPECTRUM 3PH Schematic Diagram page 2 of 3 RELEASED 26 Mar 2014...
Страница 133: ...131 V 520 MAX 50 SPECTRUM 3PH Schematic Diagram page 3 of 3 RELEASED 26 Mar 2014...
Страница 134: ...132 V 520 10 Refrigeration Diagram...
Страница 135: ...133 V 520 20 Refrigeration Diagram...
Страница 136: ...134 V 520 30 Refrigeration Diagram...
Страница 137: ...135 V 520 50 Refrigeration Diagram...
Страница 138: ...136 V 520 10 SPECTRUM Refrigeration Diagram...
Страница 139: ...137 V 520 20 SPECTRUM Refrigeration Diagram...
Страница 140: ...138 V 520 50 SPECTRUM Refrigeration Diagram Thermo King RELEASED 19 Jul 2012...
Страница 141: ......