OPERATOR’S MANUAL
670021
INCLUDING: OPERATION, INSTALLATION & MAINTENANCE
RELEASED: 11-21-03
REVISED:
10-28-16
(REV: G)
1" DIAPHRAGM PUMP
1:1 RATIO (METALLIC)
READ THIS MANUAL CAREFULLY BEFORE INSTALLING,
OPERATING OR SERVICING THIS EQUIPMENT.
It is the responsibility of the employer to place this information in the hands of the operator. Keep for future reference.
INGERSOLL RAND COMPANY LTD
209 NORTH MAIN STREET - BRYAN, OHIO 43506
(800) 495-0276
FAX (800) 892-6276
© 2016
CCN 15206428
arozone.com
SERVICE KITS
637419
for air section repair (see page 5).
637420
for fluid section repair (see page 3).
PUMP DATA
Models
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 670021
Pump Type
. . . . . . . . . . . . . Metallic Air Operated Double Diaphragm
Wetted End Material
. . . . . . . . . . . . . . . . . . . . . . . . . Aluminum
Weight
. . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . .
19 lbs (8.62 kgs)
Maximum Air Inlet Pressure
. . . . . . . . . . . 120 psig (8.3 bar)
Maximum Material Inlet Pressure
. . . . . . 10 psig (0.69 bar)
Maximum Outlet Pressure
. . . . . . . . . . . . . 120 psig (8.3 bar)
Maximum Flow Rate (flooded inlet)
. . . 35 gpm (133 lpm)
Maximum Particle Size
. . . . . . . . . . . . . . . . 1/8” dia. (3.2 mm)
Maximum Temperature Limits (diaphragm / ball / seal / seat
material)
Hytrel® . . . . . . . . . . . . . . . . . . . . . . . . . -20° to 150° F (-29° to 66° C)
Polypropylene. . . . . . . . . . . . . . . . . . 35° to 175° F (2° to 79° C)
Polyurethane . . . . . . . . . . . . . . . . . . . 10° to 150° F (-12° to 66° C)
Dimensional Data
. . . . . . . . . . . . . see page 7
Noise Level
@ 70 psig, 60 cpm . . . . . . . . . . 64.5 db(A)
The pump sound pressure levels published here have been updated
to an Equivalent Continuous Sound Level (LA
eq
) to meet the intent of
ANSI S1.13-1971, CAGI-PNEUROP S5.1 using four microphone locations.
GENERAL DESCRIPTION
The ARO diaphragm pump offers high volume delivery even at low
air pressure and a broad range of material compatibility options
are available. Refer to the model and option chart. ARO pumps
feature stall resistant design, modular air motor / fluid sections.
Air operated double diaphragm pumps utilize a pressure differen-
tial in the air chambers to alternately create suction and a positive
fluid pressure in the fluid chambers, valve checks insure a positive
flow of fluid.
Pump cycling will begin as air pressure is applied and will continue
to pump and keep up with the demand. It will build and maintain
line pressure and will stop cycling once maximum line pressure is
reached (dispensing device closed) and will resume pumping as
needed.
Figure 1
Содержание 670021
Страница 8: ...Page of 8 670021 en PN 97999 1070...