MAINTENANCE

Refer to the part views and descriptions as provided on 
pages 4 through 7 for parts identifi cation and service kit in-
formation.

Certain ARO “Smart Parts” are indicated which should be 
available for fast repair and reduction of down time.
Service kits are available to service two separate 
diaphragm pump functions: 1. AIR SECTION, 2. FLUID 
SECTION. The Fluid Section is divided further to match 
typical part Material Options.
Provide a clean work surface to protect sensitive internal 
moving parts from contamination from dirt and foreign 
matter during service disassembly and reassembly.
Keep good records of service activity and include the 
pump in preventive maintenance program.
Before disassembling, empty captured material in the 
outlet manifold by turning the pump upside down to 
drain material from the pump.

FLUID SECTION DISASSEMBLY

Remove top manifold(s).
Remove (22) balls, (19) “O” rings and (21) seats.
Remove (15) fl uid caps.
Remove (14) screws, (6) washers, (7) diaphragms and (5) 
washers.
Remove (3) “O” rings.

NOTE: Do not scratch or mar the surface of (1) diaphragm 
rod.

FLUID SECTION REASSEMBLY

Reassemble in reverse order.
Clean and inspect all parts. Replace worn or damaged 
parts with new parts as required.
Lubricate (1) diaphragm rod and (2) “O” ring with Key-
Lube “O” ring lube.
Use ARO pn 98931-T bullet (installation tool) to aid in in-
stallation of (2) “O” ring on (1) diaphragm rod.
Be certain (7) diaphragms align properly with (15) fluid 
caps before making fi nal torque adjustments on bolt and 
nuts to avoid twisting the diaphragm.
Re-check torque settings after pump has been re-started 
and run a while.

y

y

y

y

y

1.
2.
3.
4.

5.

y

y

y

y

y

y

WARNING

  = Hazards or unsafe practices which 

could result in severe personal injury, 
death or substantial property damage.

CAUTION

  = Hazards or unsafe practices which 

could result in minor personal injury, 
product or property damage.

NOTICE

  = Important installation, operation or 

maintenance information.

GENERAL DESCRIPTION

The ARO diaphragm pump off ers high volume delivery even 
at low air pressure and a broad range of material compatibil-
ity options are available. Refer to the model and option chart. 
ARO pumps feature stall resistant design, modular air motor 
/ fl uid sections.
Air operated double diaphragm pumps utilize a pressure dif-
ferential in the air chambers to alternately create suction and 
a positive fl uid pressure in the fl uid chambers, valve checks 
insure a positive fl ow of fl uid.
Pump cycling will begin as air pressure is applied and it will 
continue to pump and keep up with the demand. It will build 
and maintain line pressure and will stop cycling once maxi-
mum line pressure is reached (dispensing device closed) and 
will resume pumping as needed.

AIR AND LUBE REQUIREMENTS

WARNING

 EXCESSIVE AIR PRESSURE. Can cause pump 

damage, personal injury or property damage.

A filter capable of filtering out particles larger than 50 
microns should be used on the air supply. There is no lu-
brication required other than the “O” ring lubricant which 
is applied during assembly or repair.
If lubricated air is present, make sure that it is compatible 
with the “O” rings and seals in the air motor section of the 
pump.

OPERATING INSTRUCTIONS

Always flush the pump with a solvent compatible with 
the material being pumped if the material being pumped 
is subject to “setting up” when not in use for a period of 
time.
Disconnect the air supply from the pump if it is to be in-
active for a few hours.
The outlet material volume is governed not only by the 
air supply, but also by the material supply available at the 
inlet. The material supply tubing should not be too small 
or restrictive. Be sure not to use hose which might col-
lapse.
When the diaphragm pump is used in a forced-feed 
(fl ooded inlet) situation, it is recommended that a “check 
valve” be installed at the air inlet.
Secure the diaphragm pump legs to a suitable surface to 
insure against damage by vibration.

y

y

y

y

y

y

y

Содержание 66M150-XXX-C

Страница 1: ...aximumTemperature Limits diaphragm ball seal material E P R 60 to 280 F 51 to 138 C Hytrel 20 to 150 F 29 to 66 C Nitrile 10 to 180 F 12 to 82 C Santoprene 40 to 225 F 40 to 107 C PTFE 40 to 225 F 4 t...

Страница 2: ...Y AND PROPERTY DAMAGE Disconnect air supply line and relieve pressure from the system by opening dispensing valve or device and or carefully and slowly loosening and removing out let hose or piping fr...

Страница 3: ...ices which could result in severe personal injury death or substantial property damage CAUTION Hazards or unsafe practices which could result in minor personal injury product or property damage NOTICE...

Страница 4: ...O Ring Qty Mtl O Ring Qty Mtl XX2 637469 X2 94615 G 2 B Y325 16 4 B Y325 230 4 B XX9 637469 X9 94615 9 2 H Y328 16 4 T Y327 230 4 V XXB 637469 XB 94615 A 2 Sp Y328 16 4 T 92761 4 E COMMON PARTS Item...

Страница 5: ...0 in lbs 27 1 31 6 Nm 29 nut 120 140 in lbs 13 6 15 8 Nm LUBRICATION SEALANTS c Apply Key Lube grease 93706 1 to all O rings U cups and mating parts d Apply Loctite 271 to threads PARTS LIST 66M150 XX...

Страница 6: ...ring onto 115 spacer and insert etc NOTE Be careful to orient spacer legs away from blocking internal ports Lubricate and carefully insert 111 spool Install 117 gasket and 107 plate Lubricate and ins...

Страница 7: ...OVERTIGHTEN FASTENERS 105 screw 40 50 in lbs 4 5 5 6 Nm 123 screw 20 25 in lbs 2 3 2 8 Nm LUBRICATION SEALANTS c Apply Key Lube grease to all O rings U cups and mating parts d Apply Loctite 271 to th...

Страница 8: ...pipe should be sized at least as large as the inlet thread diameter of the pump for proper flow if high viscosity fluids are being pumped Suction hose must be a non collapsing type capable of pulling...