Ingersoll-Rand 6662AX-X-C Скачать руководство пользователя страница 3

6662AX-X-C 

Page 3 of 8

GENERAL DESCRIPTION

The ARO diaphragm pump offers high volume delivery even 
at low air pressure and a broad range of material compatibility 
options available. Refer to the model and option chart. ARO 
pumps feature stall resistant design, modular air motor / fl uid 
sections. 
Air operated double diaphragm pumps utilize a pressure dif-
ferential in the air chambers to alternately create suction and 
positive fl uid pressure in the fl uid chambers, ball checks insure 
a positive fl ow of fl uid. 
Pump cycling will begin as air pressure is applied and it will 
continue to pump and keep up with the demand. It will build 
and maintain line pressure and will stop cycling once maxi-
mum line pressure is reached (dispensing device closed) and 
will resume pumping as needed.

AIR AND LUBE REQUIREMENTS

WARNING

 

EXCESSIVE AIR PRESSURE. Can cause pump 

damage, personal injury or property damage.

A filter capable of filtering out particles larger than 50 
microns should be used on the air supply. There is no lu-
brication required other than the “O” ring lubricant which is 
applied during assembly or repair.
When lubricated air is necessary, supply the air lubricator 
with a good grade of SAE 90 wt. non-detergent oil and 
set the lubricator to a rate not to exceed one drop per 
minute.

y

y

OPERATING INSTRUCTIONS

Always fl ush the pump with a solvent compatible with the 
material being pumped if the material being pumped is 
subject to setting up” when not in use for a period of time.
Disconnect the air supply from the pump if it is to be inactive 
for a few hours.
The outlet material volume is governed not only by the air 
supply but also by the material supply available at the inlet. 
The material supply tubing should not be too small or restric-
tive. Be sure not to use hose which might collapse.
When the diaphragm pump is used in a forced-feed (fl ooded 
inlet) situation, it is recommended that a “Check Valve” be 
installed at the air inlet.
Secure the diaphragm pump legs to a suitable surface to in-
sure against damage by vibration.

y

y

y

y

y

MAINTENANCE

Refer to the part views and descriptions as provided on page 4 
through 7 for parts identifi cation and Service Kit information.

Certain ARO “Smart Parts” are indicated which should be 
available for fast repair and reduction of down time.
Service kits are divided to service two separate dia-
phragm pump functions: 1. AIR SECTION, 2. FLUID SEC-
TION. The FLUID SECTION is divided further to match 
typical part MATERIAL OPTIONS.
Provide a clean work surface to protect sensitive internal 
moving parts from contamination from dirt and foreign 
matter during service disassembly and reassembly.
Keep good records of service activity and include pump 
in preventive maintenance program.
Before disassembling empty captured material in the 
outlet manifold by turning the pump upside down to 
drain material from the pump.

y

y

y

y

y

 Viton

®

 and Hytrel

®

 are registered trademarks of the DuPont

®

  Company.  Keynar

®

 is a registered trademark of Penwell Corp 

  Santoprene

®

 is a registered trademark of Monsanto Company, licensed to Advanced Elastomer Systems, L.P.  Key-Lube

®

 is a registered trademark of Key Industries   

FLUID SECTION DISASSEMBLY

Remove top manifold(s).
Remove (22) balls, (19 and 33) “O” rings and (21) seats.
Remove (15) fl uid caps.

NOTE: Only PTFE diaphragm models use a primary dia-
phragm (7) and a backup diaphragm (8). Refer to the auxil-
iary view in the Fluid Section illustration.
4.  Remove the (6) nut, (7) or (7 / 8) diaphragms and (5) washers.
5.  Remove (3 and 4) “O” rings.
NOTE: Do not scratch or mar the surface of (1) diaphragm rod.

1.
2.
3.

FLUID SECTION REASSEMBLY

Reassemble in reverse order.
Clean and inspect all parts. Replace worn or damaged 
parts with new parts as required.
Lubricate (1) diaphragm rod and (2) “O” ring with 
KeyLube

®

 grease.

Use ARO PN / 98931-T Bullet (installation tool) to aid in 
installation of (2) “O” ring on (1) diaphragm rod.
Be certain (7) or (7 / 8) diaphragm(s) align properly with 
(15) fl uid caps before making fi nal torque adjustments on 
bolt and nuts to avoid twisting the diaphragm.
For models with PTFE diaphragms: Item (8) Santoprene 
diaphragm is installed with the side marked “AIR SIDE” to-
wards the pump center body. Install the PTFE Diaphragm 
with the side marked “FLUID SIDE” towards the fl uid cap.
Recheck torque settings after pump has been restarted 
and run awhile.

y

y

y

y

y

y

y

Содержание 6662AX-X-C

Страница 1: ...mTemperature Limits diaphragm ball seal material Polypropylene 350 to 1750 F 1 70 to 790 C P V D F 100 to 2000 F 120 to 930 C Dimensional Data see page 8 Noise Level 70 p s i 60 c p m 77 7 db A The pump sound pressure levels published here have been updated to an Equivalent Continuous Sound Level LAeq to meet the intent of ANSI S1 13 1971 CAGI PNEU ROP S5 1 using four microphone locations NOTICE A...

Страница 2: ...eturn a pump to the factory or service center that contains hazardous material y y y y y y y y y y y y y y y y Safe handling practices must comply with local and national laws and safety code requirements Obtain Material Safety Data Sheets on all materials from the supplier for proper handling instructions WARNING EXPLOSION HAZARD Models containing aluminum wetted parts cannot be used with 1 1 1 t...

Страница 3: ...NANCE Refer to the part views and descriptions as provided on page 4 through 7 for parts identification and Service Kit information Certain ARO Smart Parts are indicated which should be available for fast repair and reduction of down time Service kits are divided to service two separate dia phragm pump functions 1 AIR SECTION 2 FLUID SEC TION The FLUID SECTION is divided further to match typical p...

Страница 4: ... X5 92755 5 2 E Y328 16 2 T Y328 208 2 T 95912 4 E 92761 8 E XX9 637165 X9 94615 9 2 H Y328 16 2 T Y328 208 2 T Y327 342 4 V Y327 230 8 V XXB 637165 XB 94615 A 2 SP Y328 16 2 T Y328 208 2 T 95912 4 E 92761 8 E MANIFOLD FLUID CAP MATERIAL OPTIONS 6662XX XXX C Polypropylene P V D F 6662X3 6662X4 Item Description size Qty Part No Mtl Part No Mtl 6 Diaphragm Nut 2 93243 1 P 93243 2 K 15 Fluid Cap 2 94...

Страница 5: ... 1 94 9 Nm apply Loctite 271 to threads 25 26 27 and 124 Fluid Caps Manifold bolts 120 140 in lbs 13 6 15 8 Nm apply Loctite Nickel Antiseize to threads 38 Bolts 40 45 in lbs 4 5 5 1 Nm COLOR CODE DIAPHRAGM BALL MATERIAL COLOR COLOR E P R Blue Blue HYTREL Cream N A NEOPRENE Green Green NITRILE Black Red POLYURETHANE N A Red SANTOPRENE Cream Cream SANTOPRENE Green N A Backup PTFE White White VITON ...

Страница 6: ... Inspect and replace old parts with new parts as neces sary Look for deep scratches on metallic surfaces and nicks or cuts in O rings Take precautions to prevent cutting O rings upon instal lation Lubricate O rings with Key Lube grease Do not overtighten fasteners refer to torque specification block on view Re torque fasteners following restart y y y y y y PILOT VALVE DISASSEMBLY Remove 104 retain...

Страница 7: ...116 Figure 3 MAJOR VALVE PILOT VALVE 118 111 112 113 114 115 116 117 119 102 104 123 121 122 120 108 109 110 106 105 See cross section detail Figure 3 201 128 107 127 126 195 195 101 231 104 102 103 107 106 105 123 121 105 40 50 in lbs 4 5 5 6 Nm apply Loctite Nickel Antiseize to threads Apply Key Lube to all O rings U Cups mating parts Apply Loctite 271 to threads Apply pipe sealant to threads Ap...

Страница 8: ... sized at least as large as the inlet thread diameter of the pump for proper flow if high viscosity fluids are being pumped Suction hose must be a non collapsing type capable of pulling a high vacuum Check all joints on the inlet manifolds and suction con nections These must be air tight Inspect the pump for solid objects lodged in the dia phragm chamber or the seat area y y y y y y y DIMENSIONAL ...