background image

PAGE 4 OF 4

650502-X-B

OPERATING INSTRUCTIONS

WARNING

DO NOT EXCEED MAXIMUM OPERATING PRES-

SURE OF 100 P.S.I. (6.9 BAR) AT 100 P.S.I. (6.9 BAR) AIR INLET

PRESSURE.

WARNING

READ THE PUMP MANUAL FOR ADDITIONAL

OPERATING AND SAFETY PRECAUTIONS AND OTHER IM-

PORTANT INFORMATION.

INITIAL SETUP PROCEDURE

NOTICE

REFER TO THE INFORMATION INCLUDED WITH THE LOW PRES-

SURE HVLP GUN FOR SYSTEM SETUP INFORMATION. THE SYS-

TEM IS INTENDED FOR LOW PRESSURE APPLICATION ONLY.

Attach air supply hose, gun and low pressure material hose.

Install the connector to the air supply hose.

Attach (28) ground kit to ground tab, securing with (21) screw and

(22) nut.

Attach the ground wire to a suitable ground.

The gun air supply hose must be 5/16” i.d. minimum.

Keep containers covered to prevent contamination.

When using an agitator, install a “T” at the air inlet or use a separate

air supply source.

Nominal system settings:

Pump Outlet Material Pressure - 15 p.s.i. maximum.

Spray Gun Air Pressure - 60 p.s.i. maximum. Note: At 30 p.s.i. nomi-

nal setting it will deliver approximately 8 p.s.i. at the air cap when us-

ing 5/16” i.d. x 15’ long air hose.

Set air pressure to the pump at approximately 2x (two times) the op-

erating material pressure.

For example: If 15 p.s.i. material pressure is required, adjust the

pump air regulator / gauge pressure to approximately 30 p.s.i. Use

the material pressure regulator to adjust. Control the spray gun air

volume using the air regulator.

START-UP

1. Turn the knob on the air regulator counterclockwise to zero p.s.i.

2. Place pump and cover (with gun and hose attached) onto the con-

tainer of material.

3. The operating pressure should be set at the lowest needed to atom-

ize and deliver the paint. Start with the gun material pressure about

the same as the air supply and adjust up or down to set the pattern.

4. Start the pump to cycle by turning the air regulator knob clockwise.

The pump will cycle several strokes until pressure is built up in the

system, at which time it will stop. Check for any loose fittings or leak-

age.

PN 97999-823