https://www.ethercat.org/default.htm
RUN LED
state*
Concept
Description
Off
Off
The device is switched off
Blinking
Pre-operational
The device is in state PREOPERATIONAL
Single flash
Stopped
The device is in state STOPPED
On
Operational
The device is in state OPERATIONAL
*See a detailed description of the states in the next table:
* Possible LED states
Description
ON
The LED is always on
OFF
The LED is always off
Single flash
One short flash (~200 ms) followed by a long off phase (~1000 ms)
Double flash
Sequence of 2 short flashes (~200 ms), separated by an off phase (~200 ms).
The sequence is finished by a long off phase (~1000 ms)
Triple flash
Sequence of 3 short flashes (~200 ms), separated by an off phase (~200 ms).
The sequence is finished by a long off phase (~1000 ms)
Blinking
On and off with a frequency of ~2.5 Hz: ON for ~200 ms followed by off for ~200 ms.
Note that the specified timings can vary in up to ±20%.
6.3 EtherCAT signalling LEDs (only TRI-x/48-E-C)
Four LEDs below the CAN/EtherCAT connectors provide information regarding communication status according
to
External LEDs
The user can connect external LEDs by means of LED_RUN_K and LED_ERR_K pins in the
. These LEDs shall behave exactly the same as described above.