Procedure
Step
Action
Expected Result
13
Power on the Everest XCR with STO1= high,
STO2 = high.
-
14
Try to perform a "Motor Enable" (using
Motionlab 3 or network commands).
Power stage can be enabled, allowing motor
rotation. Check it by software (system should
enter in motor enable state) or by hardware
(checking the Motor phases voltage with a
multimeter).
If power stage cannot be enabled it could be
caused by other faults not related with STO
(over-voltage, under-voltage, etc.)
9.4.4. STO Operation States
The truth table of the STO inputs is shown next indicating the different states of the system:
Mode
State
STO1
status /
level
STO2
status /
level
Power
stage
status
STO
report
bit
status
STO
abnorm
al fault
State description
Norm
al
opera
tion
STO
Enabled
(No torque
to the
motor)
0
< 1.1 V
0
< 1.1
V
OFF
0
0
The system logic is powered,
but the STO function is
activated. Therefore, no torque
can be applied to the motor.
STO trip is reported to the MCU
and to the safety circuitry. This
is intended safe torque off with
dual-channel operation.
Torque
enabled
(STO
inactive)
1
> 3.6 V
1
> 3.6
V
Can be
enable
d
1
0
The STO function is
deactivated, and torque can be
provided to the motor. The
motor can run under firmware
control. This is the normal
operation state.