background image

19 

IM110822 

RD: AUGUST 2011 

RL; 1A 

BA 

InfraSave IEP-4024 Manual 

The Manufacturer warrants to the original consumer that this product is free from defects in material and/or 
workmanship under normal use and service for a period of one year (12 months) from the date of pur-
chase, and subject to the conditions and limitations stated herein. 

Warning: 

Use of this heater in coastal 

salt-air regions can result in corrosion of the aluminum body and reflector, and premature failure of the 
quartz lamp. Corrosion and failure resulting from use in coastal areas represents normal use in that envi-
ronment and is not covered by warranty.

 

ONE YEAR (12 Month) WARRANTY

 

Subject to the conditions and limitations stated herein and defined below, during the term of this limited 
warranty, we will supply any component part of the heater, excluding any labor , which the Manufacturer’s 
examination determines to be defective in workmanship or material for a period of one year (12 months) 
from the date of purchase. This warranty applies to the heater’s original owner, and only if the unit is in-
stalled and operated in accordance with the printed instructions accompanying the unit and in compliance 
with all applicable installation, building codes and good trade practices. Failure to maintain the equipment 
through regular maintenance or service by a qualified service technician shall void the warranty.  

 

WHAT IS NOT COVERED 

The Manufacturer shall not be responsible for any expenses, including service, labor, diagnosis, analysis, 
material or transportation/shipping charges incurred during removal, repair, or reinstallation of this product, 
or any of its components or parts.  All labor, shipping, and/or service charges shall be paid by the owner.  
This warranty does not cover products that have been modified after leaving the factory, improperly in-
stalled, misused, exposed to abuse or damaged by acts of God, negligence, accident, corrosive or con-
taminated atmosphere, water, excessive thermal shock, impact, abrasion, normal wear due to use, altera-
tion or operation contrary to the owner’s manual or if the serial number has been altered, defaced or re-
moved.  This warranty shall not apply if the voltage to the heater exceeds the rated voltage on the rating 
plate by more than 10%.  The Manufacturer shall not be liable for consequential damages arising out of, or 
in connection with, the use or performance of the product, or other indirect damages with respect to loss of 
property, revenues, or profit, or costs of removal, installation or reinstallation, or for any default or delay in 
performance by its warranty caused by any contingency beyond its control, including war, government re-
strictions, or restraints, strikes, fire, flood, acts of God, or short or reduced supply of raw materials or prod-
ucts.

 

WARRANTY PROCEDURE

 

To establish the date of purchase for any purpose under this Limited Warranty, you must retain the original 
receipt that can establish the purchase date of your unit. If you do not provide such documents, the start 
date of the term of this Limited Warranty will be based upon  the date of unit manufacture, plus thirty (30) 
days. Do not ship a heater back to       InfraSave for repair. Contact your local supplier / installer of the 
heater, or a local qualified electrician for warranty service or repair.  

 

LIMITATIONS AND EXCLUSIONS 

This document contains all warranties made by the Manufacturer and may not be varied, altered or ex-
tended by any person.  There are no promises, or agreements extending from the Manufacture other than 
the statements contained herein.  THIS WARRANTY IS IN LIEU OF ALL WARRANTIES EXPRESSED OR 
IMPLIED, TO THE EXTENT AUTHORIZED BY THE LAWS OF THE  JURISDICTION, INCLUDING SPE-
CIFICALLY THE WARRANTIES OR MERCHANTIBILITY OF FITNESS FOR A PARTICULAR PURPOSE. 
All warranties are limited in duration to 12 months. 
It is understood and agreed that the Manufacturer’s obligation hereunder is limited to repairing or replacing 
parts determined to be defective as stated above. In no event shall the Manufacturer be responsible for 
any alleged personal injuries or other special, incidental or consequential damages. As to property dam-
ages, contract, tort or other claim the Manufacturer’s responsibility shall not exceed the purchase priced 
paid for the product. 
All replacement parts will be warranted  for the unused portion of the warranty coverage period remaining 
on the applicable unit. 
Some States and authorities do not allow certain warranty exclusions or limitations on how long a warranty 
lasts or the exclusions or limitations of incidental or consequential damages.  In such cases, the above 
limitations or exclusions may not apply to you and are not intended to do so where prohibited by law.  This 
warranty gives you specific legal rights.  You may also have other rights which vary by each jurisdiction. 

InfraSave IEP SERIES HEATERS - LIMITED WARRANTY CERTIFICATE 

Содержание IEP-4024

Страница 1: ...t the heater from the power source prior to servicing Do not store or use gasoline or other flammable vapours and liquids in the vicinity of this or any other hot surface appliance Do not use or locate this model where it could fall into a bathtub or other water container Do not cover or block any surface of this appliance Do not touch this appliance while in operation Allow to cool after use Read...

Страница 2: ...al and or all local and national code requirements This publication is the intellectual property of Schwank This publication or parts thereof may not be reproduced in any form without prior written consent from Schwank Unauthorized use or distribution of this publication is strictly prohibited Schwank Group Schwank and InfraSave brands 5285 Bradco Boulevard Mississauga Ontario L4W 2A6 2 Schwank Wa...

Страница 3: ...uctions General Information 9 Locating the Heater 9 Minimum Required Clearances 10 Heater Mounting 10 5 Electrical Connection 12 6 Operating Instructions 12 7 Maintenance Instructions 13 8 Cleaning 13 9 Heater Parts 14 10 Heat Lamp Replacement 15 11 Warranty Statement 18 FIGURE 1 Recommended Mounting Comfort Area Coverage 8 FIGURE 2 Minimum Required Clearances 10 FIGURE 3 Mounting Bracket 11 FIGUR...

Страница 4: ... instruct and ensure that they do not play with the heater 7 Always disconnect power source to heater when not in use Never leave the heater unattended during operation 8 Do not operate any heater with a damaged cord or after the heater malfunctions has been dropped or damaged in any manner Return heater to an authorized service facility for examination electrical or mechanical adjustment or repai...

Страница 5: ...er may cause fire electric shock and death or injury to persons and property damage 18 Do not touch an operating heater or live parts burns electric shock and death or personal injury can result 19 Do not adjust the heater on the swivel bracket during operation Allow heater to cool before making any adjustment to heater position 20 Do not stare at the heater Lamp damage to your eyes could occur 21...

Страница 6: ...6 IM110822 RD AUGUST 2011 RL 1A BA InfraSave IEP 4024 Manual 2 HEATER DIMENSIONS WIRING SPECIFICATIONS IEP 4024 ...

Страница 7: ...bient air temperature that the design must consider Then what comfort temperature rise is desired Indoor to 65 Outdoor to Calculate the required input to get the desired average temperature rise Input Site Length x Site Width x Temperature Rise x Heat Density per Degree Example Outdoor Patio 30 ft long by 10 feet wide Desired temperature rise 20 F average over the area 30 x 10 x 20 x 2 12 000 Watt...

Страница 8: ...ecom mended Min Max Input Watts IEP 6024 6000 IEP 1520 4 1500 IEP 2024 Model H Height Above Floor Deck E Average Heat Coverage IEP 4024 4000 D Area Heated 2000 C Outer Perimeter A Distance Out B Under Heater FIGURE 1 RECOMMENDED MOUNTING COMFORT AREA COVERAGE TABLE 1 RECOMMENDED MOUNTING COMFORT AREA COVERAGE Approximate Angle of Heat Dispersion from heater The design information presented here is...

Страница 9: ...ilure the quartz lamp Corrosion and failure resulting from use in coastal areas represents normal use in that environment and is not covered by war ranty 1 The heater is designed for wall or post mounting and must be installed at least 6 feet 1 8 m above the floor 2 Ensure that clearances from the heater meet or exceed the minimum required clearances in Table 2 and Figure 2 below Above to the Floo...

Страница 10: ... the installer since the type of hardware fastening is determined by site conditions 4 Each Mounting Bracket fastens to the wall using two 2 field supplied bolts or lag screws through two holes in one side of the bracket Mount brackets to the wall with a separation distance of 35 5 8 inches 90 5 cm to fit the heater between the mounting extensions of the brackets see next page 5 Fasten the Mountin...

Страница 11: ...ning the knob fasteners 9 Once the heater position is established hand tighten both knob fasteners firmly to main tain the heater in a secure and stable position 10 Connect each lamp circuit to a 230 240 Vac 60Hz 9 Amp copper wire circuit that is properly grounded Electrical connection must be performed by a qualified electrical tradesperson Installation must conform with the latest edition Electr...

Страница 12: ...e and electric shock 5 The power cord must not come into contact with hot appliance parts or surfaces and must not pass in front of the heater 6 Do not crush the cord nor drag it over sharp edges nor place it over a heated hotplate or open flame 7 Read understand and explain and describe to other users the location function and operation of each control of the heater including all user operated de...

Страница 13: ...on below Any damaged parts or components must be repaired or replaced prior to operation Service and Repair Disconnect the heater from the power source prior to any servicing Important All repairs must be referred to qualified electrician Repairs carried out improperly or by an unqualified person may have serious conse quences for the user Any tampering with the appliance will invalidate the warra...

Страница 14: ...ower Cord Retainer Plate top side 7 Center Cover Plates top side 8 Interior Heater End Cover 9 Connection Box Face Plate 10 Connection Box 11 Terminal Block for electrical connections 12 Power Cord 13 Lamp Retainer Clips 4 14 Extension wires to lamp 2 15 1 2 Heat Lamp 1 2 Each Lamp 2000 Watts Part JE 2000 XX FIGURE 5 1 2 3 4 5 6 7 8 9 12 13 11 10 14 9 HEATER PARTS IEP 4024 Electrical Connection Bo...

Страница 15: ...AMP DO NOT TOUCH THE LAMP SURFACE WITH YOUR BARE HANDS OILS FROM YOUR SKIN WILL CAUSE DAMAGE TO THE LAMP The heater requires disassembly to replace the heat lamp Use a container to securely store disassembled components and screws Step 1 Ensure power supply is disconnected Compress the width of the protective screen to retract the wire tabs from under one edge of the heater body Rotate the lose ed...

Страница 16: ...box top surface Step 7 Loosen screws in terminal block to remove wires as required RED wires connect to Lamp 1 closer to connection box BLUE wires connect to Lamp 2 further end from box Do not disconnect power supply wires Loosen the threaded clamping collar on the Liquid Tight Connector located behind the wiring terminal Pull wires out through the Liquid Tight Connector and top of electrical conn...

Страница 17: ...es not have a lower lip Insert a fine edged slot screw driver between the heater body and the BOTTOM edge of the face plate Pry the face plate from the heater body and re move to storage Step 12 Slide the end face plates out from each end of the heater Step 13 NOTE For this Step keep the heat lamp retainer clips in place at each end of lamps Heat lamp is fragile use cau tion when feeding wires thr...

Страница 18: ...ater Step 15 IMPORTANT Wear gloves to handle the heat lamp Oils from your skin will damage the lamp The heat lamp is VERY FRAGILE HANDLE AND ASSEM BLE WITH GREAT CARE Carefully slide old heat lamp out of heater through rectan gular slot in end of reflector CAREFULLY install new heat lamp and clip in place Reverse steps above to reassemble the heater Take particular care not to damage the lamp at S...

Страница 19: ... or in connection with the use or performance of the product or other indirect damages with respect to loss of property revenues or profit or costs of removal installation or reinstallation or for any default or delay in performance by its warranty caused by any contingency beyond its control including war government re strictions or restraints strikes fire flood acts of God or short or reduced su...

Отзывы: