Sunglo™ Infrared Heaters
23
TROUBLESHOOTING
MANUAL CONTROL
Problem
Possible Causes
Pilot will not light
•
Air in gas line
•
Low gas pressure
•
Gas line turned “Off”
•
Blockage of gas line
Pilot does not stay lit
•
Damaged thermocouple
•
Corrosion of thermocouple connection to valve
•
Damaged Gas Valve
•
Wind exceeding 10 mph
Main Burner does not light
•
Low gas pressure
•
Blockage in the main orifice
•
Obstruction inside the burner
MANUAL CONTROL WITH DSI
Problem
Possible Causes
No Spark
•
Weak battery
•
Damaged Electrode
•
Ground Plate not in place
•
Loose or damaged wire
Spark will not light pilot
•
No gas to pilot
•
Electrode not sparking to pilot hood
•
Improper electrode gap (3/16”)
AUTOMATIC GAS VALVE (V SERIES)
Problem
Possible Causes
Main burner does not light
•
No power to the heater (24 VAC required)
•
Control knob not in “On” Position
ELECTRONIC IGNITION (E SERIES)
Problem
Possible Causes
No Spark to Electrode
•
Improper electrode ga (3/16”)
•
Damaged electrode or wiring
•
Damage ground wire
Gas Valve does not open
•
No power to gas valve (24 VAC required)
•
Loose or damaged wiring to gas valve
•
Damaged gas valve
Heater Shuts Down
•
Wind exceeding 10 mph
•
Electrode damaged or out of position
•
Damage electrode connection
Содержание A242
Страница 6: ...Sunglo Infrared Heaters 6 BASIC LIGHTING INSTRUCTIONS ...
Страница 10: ...Sunglo Infrared Heaters 10 HEATER MODELS ...
Страница 11: ...Sunglo Infrared Heaters 11 ...
Страница 12: ...Sunglo Infrared Heaters 12 ...
Страница 13: ...Sunglo Infrared Heaters 13 ...
Страница 14: ...Sunglo Infrared Heaters 14 ...
Страница 15: ...Sunglo Infrared Heaters 15 ...
Страница 16: ...Sunglo Infrared Heaters 16 ...
Страница 17: ...Sunglo Infrared Heaters 17 ...
Страница 18: ...Sunglo Infrared Heaters 18 ...
Страница 19: ...Sunglo Infrared Heaters 19 ...
Страница 20: ...Sunglo Infrared Heaters 20 ...
Страница 21: ...Sunglo Infrared Heaters 21 ...