11
CD1-a
Chapter 2 - Specifications
Logic inputs
Enable / Disable: ENABLE
Limit : FC+
Limit switch - : FC-
Current command: CI
Zero speed input command: CV0
Fault RESET
Logic outputs
"AOK" relay contact
Umax = 50 V, Imax = 100 mA, Pmax = 10 W
"AOK": closed if amplifier OK, open if fault
Error display
LED on front panel and diagnostic by serial link
Parameter setting
Serial link RS232
Automatic functions
Amplifier adjustment to the motor (AUTOPHASING)
Automatic regulator adjustment (AUTOTUNING)
Offset compensation on analog input
Conformity with the standards:
CE
certification
"360°" shield; equipotential according to the
wiring rules.
EMC standards:
- Immunity: EN 61000.4-2-3-4-5
- Conducted and radiated disturbances: EN 55011,Group 1,
class A
Electrical standards for industrial machines:
- EN 60204.1: - Insulator
:
1500 VAC/1 min.
- Leakage current > 30 mA (EMI filters)
Conformity with the standards:
UL
listing
"360°" shield; equipotential according to the
wiring rules.
CD1-a series have been “
c
UL
us
” listed according to UL508C
and UL840 regarding the insulator.
This product was evaluated to:
- the Third Edition of UL508C, the UL Standard for Power
Conversion Equipment, dated May 2002 for the UL Listing
(USL),
- the CSA Standard for Industrial Control Equipment, C22.2
N° 14-95, dated August 1995 for the Canadian UL Listing
(CNL).
Temperature
- storage - 20°C to + 70°C
- operation 5°C to +40°C
From 40°C on, the rated currents must be reduced of 3 % per
additional °C.
Max. temperature: 50°C
Altitude 1000
m
Moisture
< 50 % at 40°C and < 90 % at 20°C: (EN 60204.1 standard)
Condensation prohibited (storage and operation)
Cooling
Forced air (fan integrated in the CD1-a amplifier)
Check for free ventilation and no upper or lower obstruction of
the air admissions
Environment
Open chassis to be mounted in a housing protecting the drive
from conducting dust and condensation (pollution degree 2
environment)
Mounting position
Vertical
Mounting location
Closed cabinet without any conducting and/or corroding
agents and according to the room temperature requirements.
Condensation prohibited.
Weight
CD1-a-230/I: approx. 1 kg
CD1-a-400/1.8 to 7.2 A: approx. 1.5 kg
CD1-a-400/14 : approx. 3 kg
CD1-a-400/30 and 45: about 4.8 kg