background image

[ 19 ]    

EasyGluco

TM

Reviewing Your Results

INFOPIA

[ 20 ]

Testing Your Blood

STEP 3.

After you hear the 

beep

sound, the test will begin automatically and your results will appear after 9 seconds.  It should begin 

counting down from 9 seconds to 1 second on the LCD display window. The LCD display window will indicate the result of your

blood glucose level.

STEP 4.

Record the result value in your EasyGluco

TM

logbook. This will help you reference your blood glucose levels historically.  

When the testing is complete, discard the used test strip and lancet to a proper place. Make sure to retain all necessary

EasyGluco

TM

items  in the leather case for your next test. Clean the meter if necessary according to 

Maintaining the

EasyGluco

TM

Meter

.

CAUTION : 

If you receive any error messages please refer to the 

Troubleshooting

section of this Manual.  

The EasyGluco

TM

( Meter saves up to 200 test results in built-in memory and records the average glucose level for the number of days in

which you had preset to be calculated and saved. These values will appear on the LCD display window by recalling any time you want to
see it. The newest result will replace the oldest beyond the 200 saved data.

The meter enters 

Reviewing Your Results

mode by pressing the MEM button.

The first display shows the current date and time, then the
average glucose level calculation over the period that was
already pre-set.

If no data was saved, the
meter will display X and
powers off automatically
after 3 seconds.

If no data was saved for the
pre-set days for the average
glucose calculation, the
meter will display a zero and
display each value of the
past results

Содержание EasyGluco

Страница 1: ...80 Korea www infopia21 com ObelisS A Bd GeneralWahis 53 1030 Brussels Belgium Tel 32 2 732 59 54 Fax 32 2 732 60 03 E Mail mail obelis net Lancing Device GMMC Room No 1112 AceTower 9th Bldg 345 30 Kas...

Страница 2: ...Blood Glucose Monitoring System Operation Manual EasyGlucoTM...

Страница 3: ...with your healthcare professional before making any changes The EasyGlucoTM System is for in vitro diagnostic use only A warranty registration card is included with your system Please complete the thr...

Страница 4: ...ontact your local representative Before using the EasyGlucoTM Blood Glucose Monitoring System read all of the operating instructions in this Operation Manual to practice forsafeandaccuratetesting Easy...

Страница 5: ...r system to the place of purchase or contact your nearest Infopia representative EasyGlucoTM Blood Glucose Monitoring System KIT Contents EasyGlucoTM Blood Glucose Meter Test port Product Label Batter...

Страница 6: ...se Meter Display LCD display segment System Check Unit of result EasyGlucoTM Blood Glucose Test Strip The EasyGlucoTM System measures the amount of glucose in your blood Apply blood here Check here to...

Страница 7: ...ormation Store the EasyGlucoTM Test Strip vials in a cool dry place between 36 86 F 2 30 Keep out of direct sunlight Do not freeze Store test strips in it s original vials only Do not mix the test str...

Страница 8: ...o obtain accurate results The control solution test is similar to a blood test except that you use the EasyGlucoTM Control Solution instead of a drop of blood Code numbers are used to calibrate the Ea...

Страница 9: ...on test STEP 1 Insert Test Strip Insert a Test Strip with the arrow side facing up and in the direction of the arrow insert it into the test port of the Meter firmly The meter will automatically turn...

Страница 10: ...EasyGlucoTM Control Solution 11 EasyGlucoTM INFOPIA 12 The EasyGlucoTM Meter has three functional modes as settings 1 Average period 2 Unit 3 Date Time If you need to change the time or if you remove...

Страница 11: ...ton down With the correct minute on display press the MEM button and the 12 hour format AM PM setting will start flashing Press the SET button to select the appropriate time format Press the MEM butto...

Страница 12: ...ck on the lancing device Discard the used lancet to a proper place Clean the lancing device if blood or stain remains CAUTION Use a new sterile lancet every time you test Do not use lancet if protecti...

Страница 13: ...procedure from the beginning If the codes on the LCD display window and on the test strip vial do not match do the Coding The Meter procedure for accurate result Practice using the Lancing Device and...

Страница 14: ...syGlucoTM Meter CAUTION If you receive any error messages please refer to the Troubleshooting section of this Manual The EasyGlucoTM Meter saves up to 200 test results in built in memory and records t...

Страница 15: ...revent infectious diseases 2 The meter should be cared for after testing and cleaned if necessary with a soft cloth or tissue If necessary rubbing alcohol can be used to wipe away dirt on the outer su...

Страница 16: ...s with two 3 0V CR2032 or equivalent lithium batteries The batteries will provide you with enough power to perform about 5 000 tests When replacing the battery 3 0V CR2032 or equivalent lithium batter...

Страница 17: ...ution With normal result re test with blood samples two or three times HI results indicate severe hyperglycemia high blood glucose If the HI message persists please seek medical attention immediately...

Страница 18: ...ly a sufficient amount of the blood sample to a new test strip and re test Re test with a new strip Problem with the test strip Test does not start after applying blood sample The result is doubtful I...

Страница 19: ...batteries supplied with the Meter set Please fill in the warranty card attached to the set Mail or fax it back to us The EasyGlucoTM Meter has a full three year warranty from the original date of your...

Страница 20: ...Memo Memo...

Отзывы: