InFocus SP-CWRS232 Скачать руководство пользователя страница 2

Product Note

RS232 Terminal Specifications-Communication configuration

To control your projector from an LCD control panel, connect the null modem cable and set 

your computer’s serial port settings to match this communication configuration:

Command format

All commands consist of 3 alphanumeric characters followed by a request, all enclosed in 
parentheses. The request can be a read request (indicated by a “?”) or a write request (indi-
cated by 1 to 4 ASCII digits).

A read request format: (AAA?) where

(

starts the command

AAA

denotes the command

?

denotes the read request

)

ends the command

A read command returns the range and the current setting, for example

:

A write request example: (AAA####) where

(

starts the command

AAA

denotes the command

####

denotes the value to be written
(leading zeros not necessary)

)

ends the command

Some commands have ranges, while others are absolute. If a number greater than the maxi-
mum range is received, it is automatically set to the maximum number for that function. If a 
command is received that is not understood, a “?” is returned. With absolute settings, “0” is 

off, 1-9999 is on. The one exception is the Power command, where 0 is off and 1 is on.

Setting

Value

Bits per second

19,200

Data bits

8

Parity

None

Stop bits

1

Flow control

None

Emulation VT100

Function

Command

Response

Brightness 

(BRT?)

 (0-22, 10)

Volume (VOL?)

(0-80, 

0)

Lamp hours

(LMP?)

(0-9999, 421)

Function

Command

Response

Brightness 

(BRT10)

Sets the brightness to 10

Freeze 

(FRZ1) or 
(FRZ8888)

Freezes the display

Power

(PWR0)

Turns power off