background image

Accessing the Appliance

12 

 

Infoblox Installation Guide

Connecting to the Appliance

Before you can configure the Infoblox appliance through the Infoblox GUI, you must be able to make a network 
connection to it. You must use the LAN1 port to connect to the appliance. The default network settings of the LAN1 
port are 192.168.1.2/24 with a gateway at 192.168.1.1 (the HA, MGMT, and LAN2 ports do not have default 
network settings). To change these settings to suit your network, use either the LCD or the console port. 

LCD

The Infoblox appliance has an LCD and navigation buttons on its front panel. At startup, the Infoblox logo appears 
in the LCD on the front panel of the appliance. Then the LCD scrolls repeatedly through a series of display screens.

1.

To change the network settings from the default, press one of the navigation buttons. 

The LCD immediately goes into input mode.

2.

Use the navigation buttons to enter the IP address, netmask, and gateway for the LAN1 port.

You can disable LCD input functionality. To disable the LCD, refer to the 

NIOS Administrator Guide

.

Console Port

The Infoblox appliance has a male DB-9 console port on the front panel. You can log in to the appliance through this 
port and specify initial network settings using the Infoblox CLI.

Note: 

Only a properly grounded USB-to-Serial dongle is allowed to connect to the serial console port. If the dongle 

is connected to a laptop, this laptop must be grounded properly as well. Failure to do so may result in damage to 
the serial console port of the Infoblox appliance. Infoblox is not responsible for such damage.

1.

Connect a console cable from the console port of the management system to the console port of the Infoblox 
appliance. 

2.

Using a serial terminal emulation program such as Hilgraeve Hyperterminal

®

 (provided with Windows

®

 

operating systems), launch a session. The connection settings are:

Bits per second: 9600

— Stop bits: 1 

Data bits: 8

— Flow control: Xon/Xoff

Parity: None

3.

Log in using the default user name and password 

admin

 and 

infoblox

. User names and passwords are 

case-sensitive.

4.

To change the network settings from the default, enter the

 set network 

command. Then enter information 

as prompted to change the IP address, netmask, and gateway for the LAN1 port.

Infoblox >

 set network

NOTICE: All HA configuration is performed from the GUI. This interface is used only to 
configure a standalone node or to join a grid.

Enter IP address: 

LAN1 port

 

IP address

Enter netmask: [Default: 255.255.255.0]: 

netmask

Enter gateway address [Default: n.n.n.1]: 

gateway IP address

Become grid member? (y or n):

 n

After you confirm your network settings, the appliance automatically restarts.

Содержание Infoblox-250-A

Страница 1: ...omissions which may be present in this document or from use of this document This document is an unpublished work protected by the United States copyright laws and is proprietary to Infoblox Inc Disclosure copying reproduction merger translation modification enhancement or use of this document by anyone other than authorized employees authorized users or licensees of Infoblox Inc without the prior...

Страница 2: ...information refer to the Infoblox website or contact Infoblox Technical Support Company Information Infoblox is located at 4750 Patrick Henry Drive Santa Clara CA 95054 1851 USA Web www infoblox com www infoblox com support Phone 408 625 4200 Toll Free 888 463 6259 Outside North America 1 408 716 4300 Fax 408 625 4201 Product Information Hardware Models Infoblox 550 A 1050 A 1550 A 1552 A 1852 A a...

Страница 3: ...oblox approach combines the simplicity of appliances with the power of advanced distributed database technology to control and automate services while achieving availability manageability visibility and control unparalleled by conventional solutions based on legacy technologies You can configure and manage the Infoblox 250 A through an easy to use Infoblox GUI that works seamlessly in Windows Linu...

Страница 4: ...nnector Pin Assignments on page 6 Figure 2 Infoblox 250 A Front Panel Table 1 Front Panel Components Component Description USB Port Reserved for future use Console Port A male DB 9 serial port for a console connection to change basic configuration settings and view basic system functions through the CLI command line interface Use the serial cable and connection adapters that ship with the applianc...

Страница 5: ...gh availability pair connects to the network using a VIP virtual IP address HA pair nodes also use their HA ports for VRRP Virtual Router Redundancy Protocol advertisements LAN1 Port A 10 100 1000 Mbps gigabit Ethernet port that connects a NIOS appliance to the network You must use the LAN1 port to set up the appliance initially It handles all traffic if you do not enable the MGMT and LAN2 ports T...

Страница 6: ...ansmit data and the twisted pair connecting to pins 3 and 6 receive data For 1000Base T connections all four twisted pair wires are used for bidirectional traffic Figure 4 Connector Pin Assignments 2 1 3 4 5 6 7 8 9 2 1 3 4 6 5 7 8 7 8 6 5 3 4 2 1 DB 9 Connector Pin Assignments RJ 45 Connector Pin Assignments Pin 10Base T 100Base T Signal 1000Base T Signal T568A Straight Through Wire Color T568B S...

Страница 7: ...nge within which the appliance circuitry can operate Component Description Model Number An identifier of the hardware model type and software type Serial Number The serial number of the appliance Use it to register the appliance to obtain software upgrades and technical support services Air Vent An air vent that allows warm air to flow out of the appliance Do not obstruct Fan A fan to help maintai...

Страница 8: ... 240 VAC switchable 47 63 HZ 3 A Europe 208 265 VAC switchable 47 63 HZ 2 A Output Power 250 watts Power plug and cable specifications by region Region Plug Type Cable Type Max Power Rating Max Temperature Rating North America NEMA5 15P 3 prong male plug VCTF 3C 18 AWG 7A 125 V 75 C Japan NEMA5 15P 3 prong male plug VCFI 3G 12A 125 V 60 C Europe CEE7 standard VII 2 prong male plug H05VV F 6A 250 V...

Страница 9: ...e side of the appliance Note There are five evenly spaced holes on each side of the appliance You can secure the brackets to any two adjacent holes so that you can mount the appliance more or less deeply in the rack 4 Secure the bracket to the appliance with two of the screws that you removed previously 5 Secure the second bracket in the same position on the other side of the appliance 6 Attach th...

Страница 10: ...col works properly configure the following settings at the port level for all the connecting switch ports HA LAN1 and LAN2 Spanning Tree Protocol Disable For vendor specific information search for HA in the Infoblox Knowledge Base system at http www infoblox com en support support center login html Trunking Disable EtherChannel Disable IGMP Snooping Disable Port Channeling Disable Speed and Duplex...

Страница 11: ...oblox appliance Table 1 Software and Hardware Requirements for the Management System Management System Software Requirements Management System Hardware Requirements Infoblox GUI ACCESS Microsoft Internet Explorer 8 0 or Mozilla Firefox 3 5 on Microsoft Windows 7 Microsoft Internet Explorer 7 0 and 8 0 or Mozilla Firefox 3 5 on Microsoft Windows Vista Microsoft Internet Explorer 7 0 and 8 0 or Mozi...

Страница 12: ...l network settings using the Infoblox CLI Note Only a properly grounded USB to Serial dongle is allowed to connect to the serial console port If the dongle is connected to a laptop this laptop must be grounded properly as well Failure to do so may result in damage to the serial console port of the Infoblox appliance Infoblox is not responsible for such damage 1 Connect a console cable from the con...

Страница 13: ...n process This is normal because the NIOS appliance generates a self signed certificate when it first starts and your browser does not have a trusted CA certificate or a cached NIOS appliance server certificate saved from an earlier connection to authenticate the NIOS appliance certificate Also the hostname in the default certificate is www infoblox com which is unlikely to match the hostname of y...

Страница 14: ...when you make an HTTPS connection to the HA pair Settings Enter your information here Grid Name Shared Secret Host Name Grid Master s IP Address LAN1 Port IP Address and Netmask Gateway IP Address Port Settings Admin Password Local Date Time and Time Zone or NTP Server IP Address Settings Enter your information here System Name Shared Secret Host Name Virtual Router ID VIP Virtual IP Address and N...

Страница 15: ... the Infoblox GUI When an Infoblox appliance functions as an independent appliance you launch System Manager to access the Infoblox GUI When the appliance is in a grid you log in to the grid master and launch Grid Manager Figure 1 Infoblox GUI Overview Finder Panel Workspace Toolbar Help panel System Messages Breadcrumbs Navigation Global Search ...

Страница 16: ...ig Perform a DNS lookup and print the results exit Exit command interpreter help Display help ping Send ICMP ECHO quit Exit command interpreter reboot Reboot device reset Reset system settings set Set current system settings show Show current system settings shutdown Shutdown device traceroute Route path diagnostic ddns_add Send DDNS update to add a record ddns_delete Send DDNS update to delete a ...