Power plug and cable specifications by region:

Region

Plug Type

Cable Type

Max Power 
Rating

Max Temperature 
Rating

North 
America

NEMA5-15P 

 

3-prong male plug

VCTF 3C 18 AWG

7A, 125 V

75° C

Japan

NEMA5-15P 

 

3-prong male plug

VCFI 3G

12A, 125 V

60° C

Europe

CEE7 standard VII 
2-prong male plug

H05VV-F

6A, 250 V

70° C

United 
Kingdom

LP-60L 3-prong male 
plug with fuse

H05VV-F

10A, 250 V

70° C

China

RVV 300/ 500 3C X 
1.00mmSQ

IEC 320 C 13/ 
GB2099.1 G B1002

10A, 250V

70° C

Taiwan

VCTF 3x1.25mm 

 

70° C

IEC-60320-C13 (BME)/ 
BLACK-ICC

10A, 125V

70° C

Australia 
New Zealand

RVV 300/500 3C X 
1.00mmSQ

IEC 320 C13/ 
GB2099.1 GB1002

10A, 250V

70° C

India

 

South Africa

1.0/3 HO5VVF3 

 

70° C

IEC-320 C-13/BS 
546SABS

10A, 250V

70° C

Содержание Infoblox-1852-A

Страница 1: ...ical errors or omissions which may be present in this document or from use of this document This document is an unpublished work protected by the United States copyright laws and is proprietary to Inf...

Страница 2: ...rmation refer to the Infoblox website or contact Infoblox Technical Support Company Information Infoblox is located at 4750 Patrick Henry Drive Santa Clara CA 95054 1851 USA Web www infoblox com www i...

Страница 3: ...y of appliances with the power of advanced distributed database technology to control and automate services while achieving availability manageability visibility and control unparalleled by convention...

Страница 4: ...dicator lights The back panel components include the air vent and redundant power supplies which have power connectors on off switches and fans Front Panel The panel components are shown in Figure 2 a...

Страница 5: ...o a laptop this laptop must be grounded properly as well Failure to do so may result in damage to the serial console port of the Infoblox appliance Infoblox is not responsible for such damage Drive In...

Страница 6: ...ou can use the RJ 45 rollover cable and two female RJ 45 to female DB 9 adapters that ship with the appliance or a female DB 9 to female DB 9 null modem cable The RJ 45 pin assignments follow IEEE 802...

Страница 7: ...hite Green 4 not used BI_DC Blue Blue 5 not used BI_DC White Blue White Blue 6 Receive BI_DB Orange Green 7 not used BI_DD White Brown White Brown 8 not used BI_DD Brown Brown Male DB 9 Console Port R...

Страница 8: ...he power supply has power It glows red when the power supply is not fully seated or has failed It is off when the power supply has no power On Off Switch A power switch to turn the power supply on and...

Страница 9: ...ns 1 75 H x 17 4 W x 22 D 4 44 cms H x 44 19 cms W x 55 88 cms D Weight Approximately 25 pounds 11 33 kg Ethernet Ports MGMT HA LAN1 LAN2 auto sensing 10Base T 100Base T 1000Base T Serial Port DB 9 96...

Страница 10: ...I 3G 12A 125 V 60 C Europe CEE7 standard VII 2 prong male plug H05VV F 6A 250 V 70 C United Kingdom LP 60L3 prongmale plug with fuse H05VV F 10A 250 V 70 C China RVV 300 500 3C X 1 00mmSQ IEC 320 C 13...

Страница 11: ...the appliance 2 Position one bracket so that the two holes in the bracket align with two of the holes on one side of the appliance Note There are three sets of holes on each side of the appliance You...

Страница 12: ...e the problem 3 To ensure that VRRP Virtual Router Redundancy Protocol works properly configure the following settings at the port level for all the connecting switch ports HA LAN1 and LAN2 Spanning T...

Страница 13: ...te that the power supply is fully seated in the bay is powered on and is functioning properly The LED glows red to indicate the power supply is not fully seated or has failed The LED is off when the p...

Страница 14: ...Installing an Appliance 14 Infoblox Installation Guide...

Страница 15: ...blox appliance Table 1 Software and Hardware Requirements for the Management System Management System Software Requirements Management System Hardware Requirements Infoblox GUI ACCESS Microsoft Intern...

Страница 16: ...network settings using the Infoblox CLI Note Only a properly grounded USB to Serial dongle is allowed to connect to the serial console port If the dongle is connected to a laptop this laptop must be...

Страница 17: ...n process This is normal because the NIOS appliance generates a self signed certificate when it first starts and your browser does not have a trusted CA certificate or a cached NIOS appliance server c...

Страница 18: ...If you configured an HA pair use the VIP address when you make an HTTPS connection to the HA pair Settings Enter your information here Grid Name Shared Secret Host Name Grid Master s IP Address LAN1 P...

Страница 19: ...the Infoblox GUI When an Infoblox appliance functions as an independent appliance you launch System Manager to access the Infoblox GUI When the appliance is in a grid you log in to the grid master and...

Страница 20: ...g Perform a DNS lookup and print the results exit Exit command interpreter help Display help ping Send ICMP ECHO quit Exit command interpreter reboot Reboot device reset Reset system settings set Set...

Отзывы: