Infinova V2414 Скачать руководство пользователя страница 16

 

10 

3.4.4 MANCHESTER Protocol Input 

1. Input through Keyboard 

Function 

Keyboard State 

Operation 

SET PRESET 

PROGRAM 

1-32, 35-63 + SHOT 

CALL PRESET 

OPERATE 

1-32, 35-62 + SHOT 

PLIP 180

°

 

OPERATE 

65 + SHOT 

HOME POSITION 

PROGRAM 

64 + SHOT 

ENTER MENU 

PROGRAM 

65 + SHOT 

CALL AUTOSCAN 

OPERATE 

66 + SHOT 

CLEAR SCREEN 

PROGRAM 

67 + SHOT 

REMOTE RESET 

PROGRAM 

68 + SHOT 

RESUME ALARM 

OPERATE 

64 + SHOT 

SET PATTERN 1 

PROGRAM 

70 + SHOT 

SET PATTERN 2 

PROGRAM 

71 + SHOT 

SET PATTERN 3 

PROGRAM 

72 + SHOT 

SAVE PATTERN 

PROGRAM 

69 + SHOT 

CALL PATTERN 1 

OPERATE 

70 + SHOT 

CALL PATTERN 2 

OPERATE 

71 + SHOT 

CALL PATTERN 3 

OPERATE 

72 + SHOT 

 

2. Input through Matrix Switcher 

Function 

Keyboard State 

Operation 

SET PRESET 

PROGRAM 

1-32, 35-63 + SHOT 

CALL PRESET 

OPERATE 

1-32, 35-60 + SHOT 

PLIP 180

°

 

OPERATE 

65 + SHOT 

HOME POSITION 

PROGRAM 

64 + SHOT 

ENTER MENU 

PROGRAM 

65 + SHOT 

CALL AUTOSCAN 

OPERATE 

66 + SHOT 

CLEAR SCREEN 

PROGRAM 

67 + SHOT 

REMOTE RESET 

PROGRAM 

68 + SHOT 

SET PATTERN 1 

PROGRAM 

70 + SHOT 

SET PATTERN 2 

PROGRAM 

71 + SHOT 

SET PATTERN 3 

PROGRAM 

72 + SHOT 

SAVE PATTERN 

PROGRAM 

69 + SHOT 

CALL PATTERN 1 

OPERATE 

70 + SHOT 

CALL PATTERN 2 

OPERATE 

71 + SHOT 

CALL PATTERN 3 

OPERATE 

72 + SHOT 

 

Содержание V2414

Страница 1: ... the coax Code Converters are used to convert HSDL RS 485 control code or Manchester control code from Infinova series video matrix switchers to Up the coax control signal for control over the front end dome cameras or receivers V2414 series Up the coax Code Converters are compatible with HSDL RS 485 and MANCHESTER protocol Besides the input protocols for V2414 series Up the coax Code Converters a...

Страница 2: ......

Страница 3: ...ode Converters complies with Part 15 of the FCC rules Operation is subject to the following two conditions z This device may not cause harmful interference z This device must accept any interference received including interference that may cause undesired operation V2414 Series Up the coax Code Converters has been tested and found to comply with the limits for Class A digital device pursuant to Pa...

Страница 4: ...mmended by manufacturer z Position power source and related wires to assure they will be kept away from ground and access way z Refer all service matters to qualified personnel z Save product packaging to ensure availability of proper shipping containers for future transportation Indicates that the un insulated components within the product may carry a voltage harmful to humans Indicates operation...

Страница 5: ...hapter III System Setting and Operation 5 3 1 Setting for control protocols 5 3 1 1 DIP Switch 5 3 1 2 Select Input Protocol 5 3 2 Protocol and Baud Rate Setting for RS 485 Input 5 3 2 1 DIP Switch 5 3 2 2 Select Communication Protocol and Baud Rate 6 3 3 Camera Address Group 6 3 3 1 DIP Switch 6 3 3 2 Camera Address Group Setting 6 3 4 Dome Control Operations 7 3 4 1 INFINOVA Protocol Input 7 3 4...

Страница 6: ......

Страница 7: ... 16 dome cameras or receivers z Priority levels setting for all input protocols z Multiple protocols and baud rate optional for RS 485 input z Expandable super dome or receiver addresses z Communicates with Infinova series matrix switchers via Manchester code HSDL or RS 485 z Plug in terminal connector available z Compatible with Infinova series video matrix switching system 1 4 Panels Infinova R ...

Страница 8: ...g Do not connect the V2414 series units to the primary power source until ALL connections and switch settings have been completed and verified 2 3 HSDL Connection There is one DATALINE input output on the V2414 real panel V2414 series Up the coax Code Converters convert HSDL from Infinova series video matrix switchers V2015 V2020 or V2040 to 16 Up the coax control signal outputs Please refer to fi...

Страница 9: ...series Up the coax Code Converters S Connect one end of the shield cable to the S terminal of the control code source Connect the opposite end of the shield cable to the S terminal of V2414 series Up the coax Code Converters Note Use 18 AWG shielded 2 wire cable Belden 8760 or equivalent for code line connections IN OUT DATALINE MANCHESTER RS485 B S W R GND R SW1 SW2 VIDEO OUTPUT VIDEO INPUT 1 2 3...

Страница 10: ...NPUT 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 V2414 Figure 2 3 RS 485 code input 2 6 Connection For Up the coax Control Signal Output There are 16 BNC video inputs on the V2414 real panel These video inputs could simultaneously be used for Up the coax control signal outputs to control over the dome cameras Please refer to figure 2 4 Super Dome Super Dome I N OU...

Страница 11: ...he DIP switch labeled SW2 is used to select input protocols and camera address The new settings could be effective only after V2414 is powered off and restarted Please refer to the table 3 1 for details on SW2 Table 3 1 DIP Switch SW2 1 2 3 4 5 6 7 8 Input Protocol Camera address 3 1 2 Select Input Protocol V2414 series Up the coax Code Converters could receive HSDL input Manchester code input or ...

Страница 12: ...1 1 65 80 0 0 0 1 0 0 81 96 0 0 0 1 0 1 97 112 0 0 0 1 1 0 113 128 0 0 0 1 1 1 129 144 0 0 1 0 0 0 145 160 0 0 1 0 0 1 161 176 0 0 1 0 1 0 177 192 0 0 1 0 1 1 193 208 0 0 1 1 0 0 DIP Switch SW2 Camera Group 3 4 5 6 7 8 209 224 0 0 1 1 0 1 225 240 0 0 1 1 1 0 241 256 0 0 1 1 1 1 257 272 0 1 0 0 0 0 273 288 0 1 0 0 0 1 289 304 0 1 0 0 1 0 305 320 0 1 0 0 1 1 321 336 0 1 0 1 0 0 337 352 0 1 0 1 0 1 3...

Страница 13: ... TO B W OPERATE 89 SHOT SET PATTERN 1 PROGRAM 70 SHOT SET PATTERN 2 PROGRAM 71 SHOT SET PATTERN 3 PROGRAM 72 SHOT SET PATTERN 4 PROGRAM 73 SHOT SAVE PATTERN PROGRAM 70 71 72 73 SHOT CALL PATTERN 1 OPERATE 70 SHOT CALL PATTERN 2 OPERATE 71 SHOT CALL PATTERN 3 OPERATE 72 SHOT CALL PATTERN 4 OPERATE 73 SHOT SET AUTOPAN OPERATE 92 SHOT SAVE AUTOPAN OPERATE 93 SHOT CALL AUTOPAN OPERATE 98 SHOT 2 Input ...

Страница 14: ... 73 SHOT SAVE PATTERN PROGRAM 69 SHOT CALL PATTERN 1 OPERATE 70 SHOT CALL PATTERN 2 OPERATE 71 SHOT CALL PATTERN 3 OPERATE 72 SHOT CALL PATTERN 4 OPERATE 73 SHOT 2 Input through Matrix Switcher Function Keyboard State Operation SET PRESET PROGRAM 1 32 35 127 SHOT CALL PRESET OPERATE 1 32 35 58 74 127 SHOT PLIP 180 OPERATE 33 SHOT HOME POSITION OPERATE 34 SHOT ENTER MENU PROGRAM 66 95 SHOT CALL AUT...

Страница 15: ...3 SHOT SAVE PATTERN PROGRAM 69 SHOT CALL PATTERN 1 OPERATE 70 SHOT CALL PATTERN 2 OPERATE 71 SHOT CALL PATTERN 3 OPERATE 72 SHOT CALL PATTERN 4 OPERATE 73 SHOT 2 Input through Matrix Switcher Function Keyboard State Operation SET PRESET PROGRAM 1 32 35 127 SHOT CALL PRESET OPERATE 1 32 35 58 74 127 SHOT PLIP 180 OPERATE 33 SHOT HOME POSITION OPERATE 34 SHOT ENTER MENU PROGRAM 66 95 SHOT CALL AUTOS...

Страница 16: ...72 SHOT SAVE PATTERN PROGRAM 69 SHOT CALL PATTERN 1 OPERATE 70 SHOT CALL PATTERN 2 OPERATE 71 SHOT CALL PATTERN 3 OPERATE 72 SHOT 2 Input through Matrix Switcher Function Keyboard State Operation SET PRESET PROGRAM 1 32 35 63 SHOT CALL PRESET OPERATE 1 32 35 60 SHOT PLIP 180 OPERATE 65 SHOT HOME POSITION PROGRAM 64 SHOT ENTER MENU PROGRAM 65 SHOT CALL AUTOSCAN OPERATE 66 SHOT CLEAR SCREEN PROGRAM ...

Страница 17: ... SHOT REMOTE RESET PROGRAM 68 SHOT RESUME ALARM OPERATE 64 SHOT B W TO COLOR OPERATE 68 88 SHOT COLOR TO B W OPERATE 69 89 SHOT SET PATTERN 1 PROGRAM 70 SHOT SET PATTERN 2 PROGRAM 71 SHOT SET PATTERN 3 PROGRAM 72 SHOT SET PATTERN 4 PROGRAM 73 SHOT SAVE PATTERN PROGRAM 69 SHOT CALL PATTERN 1 OPERATE 70 SHOT CALL PATTERN 2 OPERATE 71 SHOT CALL PATTERN 3 OPERATE 72 SHOT CALL PATTERN 4 OPERATE 73 SHOT...

Страница 18: ... Manchester Plug in terminal connector triple shield Electrical Voltage 120VAC 60Hz 230VAC 50Hz Power consumption 8W Mechanical Dimension 1 74 H 19 0 W 10 43 D 44 4mm H 483mm W 265mm D Weight 4 4 lb 2 0 kg Mount Rack mount desk or wall mount optional Environment Temperature 0 40 32 104 Moisture 0 90 RH Non condensing ...

Страница 19: ...ameter shall be 0 8000mm A lower diameter value tends to cause voltage loss and even system instability 0 8000 1 000 1 250 2 000 10 283 86 451 137 716 218 1811 551 20 141 42 225 68 358 109 905 275 30 94 28 150 45 238 72 603 183 40 70 21 112 34 179 54 452 137 50 56 17 90 27 143 43 362 110 60 47 14 75 22 119 36 301 91 70 40 12 64 19 102 31 258 78 80 35 10 56 17 89 27 226 68 90 31 9 50 15 79 24 201 6...

Страница 20: ...rhead wiring is prohibited because it s more likely to encounter lightning strike Use shielded cables or thread the cables through metal tubes for burial thus to ensure the electric connection to the metal tube In case it s difficult to thread the cable through the tube all the way it s acceptable to use tube threaded cables only at both ends of the transmission line yet the length in burial shoul...

Страница 21: ......

Страница 22: ...Infinova 51 Stouts Lane Monmouth Junction NJ 08852 U S A Tel 1 888 685 2002 USA only 1 732 355 9100 Fax 1 732 355 9101 sales infinova com V2 1 1107 ...