5-Specifications for wiring
The interconnecting cables used must be UL certified and must meet the requirements of the CEI 64/8 standard for video door entry
systems:
-UTP CAT 5e for internal sections dedicated to video door entry systems only
-FTP CAT 5e for sections shared with voltage cables
-UTP CAT 5e for external sections with PVC protection sheath
All cables must be LSZH for Low Smoke Zero Halogen fire behaviour.
The interconnection cables
must not exceed a maximum length of 100 meters
.
5.1-How to wire an Ethernet cable
Material:
- UL certified CAT 5 (or higher) Ethernet cable.
- UL certified RJ45 connectors.
- Electrician's scissors.
- Crimping tool for RJ45 connectors
-Tester for ethernet cables
Procedure:
1) Strip the cable (about 10mm) taking care not to damage the insulation
of the individual cables.
2) Sort the cables as shown in the figure and even them up cutting the excess.
3) Insert the cables into the RJ45 connector.
Check that the order of the cables remains unchanged after inserting the
connector.
4) Crimp the cable using the appropriate clamp making sure that the
contacts perforate the cable insulation and enter correctly into their seat.
5) Check the cable with the tester.
If the test is unsuccessful it is necessary to carry out the procedure again.
Note: For the correct operation of the cable, the procedure must be
carried out on both ends of the Ethernet cable in the same way.
CABLES SORTING
PIN
Colour
CABLE
1
White-Orange
2
Orange
3
White-Green
4
Blue
5
White-Blue
6
Green
7
White-Brown
8
Brown
Material
Procedure