Infinite Transtector ALPU PTP INJ Скачать руководство пользователя страница 2

800.882.9110  |  208.772.8515  |  www.transtector.com

ALPU PTP INJ

INSTALLATION NOTES

The ALPU PTP INJ is intended to be installed indoors or outdoors, on wall or pole 

mount applications. The unit features mounting feet on the sides that mount on 4” 

center-to-center holes with #10 sized hardware. The mount foot also adapts to 4” 

diameter pole mounting kits with a 4.5” center-to-center holes and larger hardware.  

Communication cables with the RJ45 connectors already installed can feed directly 

into the enclosure. The enclosure features has an integral retention feature that 

grips the cable with a screw down bracket. A pole mount adapter kit (pn 1000-1164) 

is available to meet installations on a wide range of pole diameters from 2” metal 

fence poles to 10” diameter utility poles.

INSTALLATION INSTRUCTIONS

1. 

Remove the cover by removing the screw on the front of the unit.

2.  

Mount the device using the two mounting holes, as close to the equipment  

 

to be protected as possible with the strain reliefs facing the ground as    

 

shown in Figure 1.

3.  

Connect one Ethernet cable between the Transceiver and the protection  

 

module using the “SURGE” RJ45 jack.

4.  

Connect one Ethernet cable between the Powered End Station and the   

 

protection module using the “PROTECTED” RJ45 jack.

5.  

For Power-over-Ethernet applications, connect the external power & return  

 

conductors (±70 Vdc / 1A max) to the screw terminals for the appropriate  

 

signal pair lines to be powered.  

 

For IEEE 802.3-2012 Mode A, connect the power and return conductors  

 

(up to 14 AWG/2.5mm2) to the “Mode A” connector.  This will carry the    

 

power on signal pairs 1/2 and 3/6.  

 

For IEEE 802.3-2012 Mode B, connect the power and return conductors to  

 

the “Mode B” connector. This will carry the power on signal pairs 4/5 & 7/8. 

 

See the Application Diagram (Figure 2) for further information.  

 

Note:  For custom applications, any two of the four screw terminals can 

 

be used to carry the power and return conductors across different pair    

 

groupings as required.  

6.  

The ALPU incorporates a 1/4-20 ground stud. Attach a ground reference  

 

wire (minimum 8 AWG) as short as possible (less than 3 feet) between this  

 

stud and the site grounding point. The two optimum ground connection    

 

points are shown on the metal enclosure (see Figure 1). 

 

Refer to local codes and equipment manufactures standards before  

 

 installation.

7.  

Replace cover.

    1200-452 Rev B

Figure 2 - Application Diagram

Figure 1 - Mechanical Outline Drawing (in[mm])