2
Output mode
Relay
(
DC30V/1A,AC125V/0.3A
)
Normal state
Normally open (open)
Normally closed (connection)
Alarm status
Normally closed (connection) Normally open (open)
Analog output
4-20mA
Signal Output
Electrical Interface
Analogue Output (Relay Output): 4-20 mA
Configuration Mode
Function
PIN
Color
+Vcc
1
Brown
Switching COM
2
White
GND
3
Blue
Switching out1
4
Black
Signal Output
Analog
5
Grey
Key Introduction
S1 and S2 keys can be used to set the switching output.
S2 key is used to select the functions and set values.
S1 key is used to confirm and set the shift operation of
display. If a setting is not confirmed within 60 seconds, the
unit will automatically exit the setting mode and enter nor-
mal measurement mode. The current temperature will be
displayed.
Normal Temperature Display Status:
Long press S2 Key, it will show 4 “Zero” for users to set the
password, short press S2 Key to change the setting value. S1
key is for adjusting the display location. When the user inputs
password “8888”, long press S1 Key to enter the “User Setup”.