ADS-270 User Guide 

20 

7. Command Summary 

7.1 Configuration Commands 

Cmd 

Description 

Syntax 

Comments 

0160  Clear Event Log 

cmd 

  

0183  Set Factory Defaults 

cmd,cmd 

  

0205  Reset Unit Operation 

cmd,cmd 

  

0301  Set Device ID 

cmd,id,p 

id: unit ID, p: password 

0790  Show Status Messages 

cmd 

  

0791  Hide Status Messages 

cmd 

  

1150  Enable Counter 

cmd,n 

n: counter 

1154  Set Counter Scale Factor 

cmd,n,f 

n: counter, f: factor 

1158  Set Counter Auto Clear 

cmd,n,c 

n: counter, c: auto clear  
(0: no, 1: yes) 

1160  Clear Counter Configuration 

cmd,n 

n: counter 

1180  Clear Counter 

cmd,n 

n: counter 

1181  Preset Counter 

cmd,n,v 

n: counter, v: value 

1200  Set AI Configuration 

cmd,n,ssl,ssh,sl,sh 

ssl/ssh: sensor scale l/h,  
sl/sh: User scale l/h 

1210  Clear AI Configuration 

cmd,n 

n: AI 

1230  Set SDI-12 Channel Configuration 

cmd,n,a,m,i 

n: SDI AI, a: sensor address, 
m: parameter set, i: 
parameter index 

1238  Clear SDI-12 Channel Configuration 

cmd,n 

n: SDI AI 

1239  Clear All SDI-12 Channel Configuration 

cmd 

  

1240  Set Modbus Trigger Command 

cmd,a,r,v 

a: address, r: reg, v: value 

1241  Set Modbus Channel Configuration 

cmd,n,a,c,sr,nr 

n: Modbus AI, a: address, c: 
command, sr: start reg, nr: 
number of regs 

1248  Clear Modbus Channel Configuration 

cmd,n 

n: Modbus AI 

1249  Clear All Modbus Channels Configuration  cmd 

  

1250  Set Massa AI Configuration 

cmd,n,a,u,o 

n: Massa AI, a: address, u: 
unit (0:in, 1:cm), o: offset 

1259  Clear Massa AI Configuration 

cmd,n 

n: Massa AI 

1291  Set AI Power Up Delay 

cmd,d 

d: delay (sec) 

1310  Set Send Period 

cmd,p 

p: period (minutes) 

1600  Set Unit RTC Time 

cmd,d,m,y,h,n,s 

d: day, m: month, y: year, h: 
hour, n: minutes, s: seconds 

9900  Save LoRa Params to NV RAM 

cmd 

 

5000  Join ABP Method 

cmd 

 

9300  Send Module Cmd with 2 Responses 

cmd,s 

s: String  

9400  Send Module Cmd with 1 Responses 

cmd,s 

s: String  

9410  Set LoRa Device Address 

cmd,s 

s: device address 

9420  Set LoRa Device EUI 

cmd,s 

s: device EUI 

9430  Set LoRa Application EUI 

cmd,s 

s: application EUI 

9440  Set LoRa Network Session Key 

cmd,s 

s: network session key 

9450  Set LoRa Network Application Key 

cmd,s 

s: network application key 

9460  Set LoRa Data Rate 

cmd,n 

n: data rate (0-7) 

9470  Set LoRa Up Frame Counter 

cmd,n 

n: up frame counter (0 - 
4294967295) 

9480  Set LoRa Power Index 

 

p: 1-5 

 

 

cmd,p 

 

 

Содержание AERINOS ADS-270

Страница 1: ...AERINOS LoRaWAN IoT Platform ADS 270 LoRa End Node User Guide...

Страница 2: ...errors or omissions Infinite Ltd reserves the right to change the specifications of the hardware and software described in this guide at any time without prior notice No part of this guide may be rep...

Страница 3: ...SDI 12 Serial Bus 11 3 8 Wiring the RS 485 Bus 11 4 Device configuration 12 4 1 Configuring DI1 as Counter input 12 4 2 Configuring AI1 as Analog Input 12 4 3 Configuring the SDI 12 channels 13 4 4 C...

Страница 4: ...ery powered end node for the LoRa network The unit is available for the 863 to 870 MHz band It incorporates two inputs one digital with pulse counter capability and one analog as well as multiple exci...

Страница 5: ...lic operation The transition between the two operation modes is uninterruptible 3 Operation suspension for the device configuration 3 Hardware setup 3 1 Packing list 1 ADS 270 Unit 2 Lithium Thionyl B...

Страница 6: ...nit can be supplied through the USB connector for configuration and test Caution Remove the external power supply J3 if applied before connecting the USB connector J2 Battery connector J3 External pow...

Страница 7: ...5 AI1 Analog Input 3 3 3 Switches S1 Test mode button 3 4 Battery installation WARNING Pay attention to the correct polarity during battery installation The right polarity is marked up on the Battery...

Страница 8: ...ADS 270 User Guide 8 3 5 Wiring the digital Counter Input COM GND Digital Input states are Contact closed Input state ON logical H Contact open Input state OFF logical L...

Страница 9: ...tion outputs 12V 5V to supply external transducers The excitation output switches ON OFF according to the selected message transmission period see 4 5 2 Low power transducers are recommended for prese...

Страница 10: ...3 AD592 temperature transducer 25 C 105 C Scale settings 25 C 105 C Sensor Output 0 641V 0 977V Raw scale 2625 4001 3 6 4 TMP36 temperature transducer 40 C 50 C Scale settings 40 C 50 C Sensor Output...

Страница 11: ...ed commands for sensor configuration in terminal mode ADS 200 can collect data from several SDI 12 sensors for a total amount of 8 measurement channels SDI 12 connections J5 2 SDI data line J4 3 GND J...

Страница 12: ...r 4 1 1 Counter Scale factor 1154 n f 1154 Command ID n 1 CNT number f 0 000 0 999 Counter Scale factor 4 1 2 Set Counter Clear Mode 1158 n c 1158 Command ID n 1 CNT number m 0 1 0 No Clear Totalizer...

Страница 13: ...mmands 4 3 1 SDI 12 acquisition scheme ADS 270 sends a start measurement command to the SDI 12 serial bus aMm where a sensor address M Start measurement command m void or 1 9 Measurement set aM or aM1...

Страница 14: ...is 9 the polarity sign 7 digits the decimal point Example A soil measurement sensor returns three parameters 1 Soil moisture in Water fraction by Volume wfv 2 Soil Conductivity in Siemens Meter S m 3...

Страница 15: ...a RS 485 address r Register v Value 4 4 2 Clear MODBUS channel configuration The command clears a MODBUS channel configuration 1248 n 1248 Command ID n Channel number 4 4 3 Clear all MODBUS channels...

Страница 16: ...channel The minimum value is 1 minute The value of this parameter affects strongly the battery life 1292 p p 1 255 min 4 6 Message Format The message is in ASCII format and has a fixed length of 12 b...

Страница 17: ...ion EUI 4 7 4 Set the Network Session Key The command sets the Network Session Key 9440 s s 16 byte hexadecimal number representing the network session key 4 7 5 Set the Network Application Key The co...

Страница 18: ...ng the unit to a PC and using a terminal program to pass the ASCII commands to the unit according to the scheme Command Parameters CR The terminal settings should be Baud rate 115200 bps Data bits 8 P...

Страница 19: ...urrent 44 5 mA Radio characteristics 863 870 MHz Band Uplink data rate TX up to 300Kbps with FSK modulation Max output power 14dBm Digital inputs 1 0 30VDC or potential free contacts Pulse counters 1...

Страница 20: ...a r v a address r reg v value 1241 Set Modbus Channel Configuration cmd n a c sr nr n Modbus AI a address c command sr start reg nr number of regs 1248 Clear Modbus Channel Configuration cmd n n Modb...

Страница 21: ...rrection Factor cmd n r c n AI r real value c corrected value 9100 Get Correction Factor cmd n n AI 9210 Send SDI Command cmd s s SDI command string 9220 Send Modbus Command cmd a c p1 p2 a address c...

Отзывы: