![Infineon XENSIV BGT60TR13C Скачать руководство пользователя страница 34](http://html.mh-extra.com/html/infineon/xensiv-bgt60tr13c/xensiv-bgt60tr13c_user-manual_2055086034.webp)
34 of 59
2022-23-05
User Guide for XENSIV™ K
IT CSK BGT60TR13C
Table of contents
Title
Description
•
Ambient temperature: 18 to 24°C
•
Relative Humidity (RH): 35 to 70 percent
Target applications
•
Homes, offices, commercial buildings
6.4
Mounting guidelines and coverage
•
The following mounting guidelines are recommended for the HW unit (radar wing board and rapid IoT
baseboard) of the CSK:
Attention: Make sure there are no moving objects or swinging doors in the field of view of the radar!
o
Top/ceiling mount:
▪
Mounted at a height of up to 3 m from the ground; sensor board longer edge is
perpendicular to the passage.
▪
It is recommended to limit the maximum range of the solution to the height of the sensor
board from the ground for good performance.
o
Side mount:
▪
Portrait orientation at around 1.1 to 1.5 m on a wall/door/pillar in such a way that the
radar sensor (on the top side of the board) is facing the entry/exit passage from the side
for people counting.
▪
For side mounting, it is recommended to set the maximum range parameter based on
the width of the entrance in such a way that it is less than the distance of the sensor to
the wall (if there is one).
•
Field of view (FoV) is shown in Figure 32, below.
Figure 32
Radar mounted on the side of the door (left) and at the top of the door with the longer edge
perpendicular to the passage (right)