Technical Reference Manual
002-29852 Rev. *B
2.3.9.6.41 CANFD_CH_TXBCF
Description:
Tx Buffer Cancellation Finished
Address:
0x405200DC
Offset:
0xDC
Retention:
Retained
IsDeepSleep:
No
Comment:
Default:
0x0
Bit-field Table
Bits
7
6
5
4
3
2
1
0
Name
CF [7:0]
Bits
15
14
13
12
11
10
9
8
Name
CF [15:8]
Bits
23
22
21
20
19
18
17
16
Name
CF [23:16]
Bits
31
30
29
28
27
26
25
24
Name
CF [31:24]
Bit-fields
Bits Name
SW
HW
Default or
Enum
Description
0:31
CF
R
RW
0
Cancellation Finished
Each Tx Buffer has its own Cancellation Finished bit.
The bits are set when the corresponding
TXBRP bit is cleared after a cancellation was
requested via TXBCR. In case the corresponding
TXBRP bit was not set at the point of cancellation, CF
is set immediately. The bits are reset when a
new transmission is requested by writing a '1' to the
corresponding bit of register TXBAR.
0= No transmit buffer cancellation
1= Transmit buffer cancellation finished
98
2022-04-18
TRAVEO™ T2G Automotive MCU: TVII-B-E-4M body controller entry registers