3.3.1
Data Frame
The structure of a data frame sent to the device is shown in
. The parity bits PE (bit 17) and PO (bit 18)
have to be set in the same way as for the command frame (bit 0 is the LSB, bit 20 is the MSB):
bit0 XOR bit2 XOR bit4 XOR …. XOR bit20 = 0
bit1 XOR bit3 XOR bit5 XOR …. XOR bit19 = 0
Figure 3-6 Data Frame to Sensor
shows a the structure data frame received from the sensor. Instead of a zero bit followed by two parity
bits, the least significant 3 bits of the address used for the readout are transmitted together with the data. This is
to check the plausibility of the received data.
Figure 3-7 Data Frame from Sensor
3.3.2
Interface Specification
specifies the operating conditions of the programming interface, which must be met in order to ensure
correct operation of the TLE4997 during programming. All specified parameters refer to these operating
conditions, unless otherwise noted.
The specification for timings and electrical levels of the programming interface is shown in
. The meaning
of the timing parameters is illustrated in
.
Table 3-3
Operating Range of the Programming Interface
Parameter
Symbol
Values
Unit
Note / Test Condition
Min.
Typ.
Max.
Supply voltage
V
DD
4.5
–
5.5
V
–
Supply buffer capacitance C
S
47
–
1000
nF
V
DD
to GND
Load capacitance
C
L
0.0
1)
1) >47nF soldered to the device required in case that connectivity failures can influence the programming voltage.
–
210
nF
OUT to GND
Ambient temperature
T
PRG
10
–
60
°C
during programming
Number of programming
cycles
N
PRG
10
Cycles Programming is allowed only at
start of lifetime
Programming time
t
PRG
–
100
–
ms
For complete memory
Programming start time
t
PRG_START
–
–
19
ms
To start programming mode, a
first read command shall be sent
within this time window after
power-up
1
0
P
O
P
E
DATA (16bit)
1
MSB (bit 20)
LSB (bit 0)
1
ADR (3 LSBs)
DATA (16bit)