background image

Evaluation Kit Software – Installation (4/6)

“Confirm view”: in this view the 

user shall confirm the 

installation.

29

2020-10-08

Copyright © Infineon Technologies AG 2020. All rights reserved.

Содержание TLE4966 MS2GO

Страница 1: ...TLE4966 MS2GO Quick Start V1 0 0 ...

Страница 2: ...ument Contents Description Content Use Cases Hardware description design Software Installation Process Software features 1 2 3 4 5 6 2 2020 10 08 Copyright Infineon Technologies AG 2020 All rights reserved ...

Страница 3: ...Agenda Description Content Use Cases Hardware description design Software Installation Process Software features 1 2 3 4 5 6 3 2020 10 08 Copyright Infineon Technologies AG 2020 All rights reserved ...

Страница 4: ...hat is enabling the evaluation of the TLE4966G lateral Hall latch and TLE4966V 1G vertical Hall latch The TLE4966 MS2GO Evaluation kit is offered in one version combining both sensors above mentioned 4 2020 10 08 Copyright Infineon Technologies AG 2020 All rights reserved ...

Страница 5: ...ise magnetic switching points and high temperature stability are achieved by active compensation circuits and chopper techniques on chip They provide a speed signal at Q2 for every magnetic pole pair and a direction information at Q1 which is provided before the speed signal TLE4966V 1G TLE4966G 5 2020 10 08 Copyright Infineon Technologies AG 2020 All rights reserved ...

Страница 6: ...Agenda Description Content Use Cases Hardware description design Software Installation Process Software features 1 2 3 4 5 6 6 2020 10 08 Copyright Infineon Technologies AG 2020 All rights reserved ...

Страница 7: ...get microcontroller XMC4200 as debugger microcontroller TLE4966G TLE4966V 1G TLI493D W2BW as magnetic probe auxiliary circuitry Ferrite block magnet FE Q 07 07 05 for easy magnetic basic evaluation Paper container box 7 2020 10 08 Copyright Infineon Technologies AG 2020 All rights reserved ...

Страница 8: ...Infineon Out Of Shaft 3D sensor control The Out Of Shaft 3D sensor control is not included in the evaluation kit content therefore has to be ordered separately The Out Of Shaft 3D sensor control ordering code SP003475178 8 2020 10 08 Copyright Infineon Technologies AG 2020 All rights reserved ...

Страница 9: ...Agenda Description Content Use Cases Hardware description design Software Installation Process Software features 1 2 3 4 5 6 9 2020 10 08 Copyright Infineon Technologies AG 2020 All rights reserved ...

Страница 10: ...case highlights the vertical Hall technology used in TLE4966V 1G sensor The magnet placement for this application is highlighted using as example the Out Of Shaft 3D Sensor control 10 2020 10 08 Copyright Infineon Technologies AG 2020 All rights reserved ...

Страница 11: ...e case highlights the lateral Hall technology used in TLE4966G sensor The magnet placement for this application is highlighted using as example the Out Of Shaft 3D Sensor control 11 2020 10 08 Copyright Infineon Technologies AG 2020 All rights reserved ...

Страница 12: ... line and electrically connect it remotely to the remaining PCB or to his own electrical setup In this use case the user loses connectivity to the 3D Sensor magnetic probe The side pin header slots are directly connected to sensor outputs Cut across this line 12 2020 10 08 Copyright Infineon Technologies AG 2020 All rights reserved ...

Страница 13: ...Agenda Description Content Use Cases Hardware description design Software Installation Process Software features 1 2 3 4 5 6 13 2020 10 08 Copyright Infineon Technologies AG 2020 All rights reserved ...

Страница 14: ...Pinout Description 14 2020 10 08 Copyright Infineon Technologies AG 2020 All rights reserved ...

Страница 15: ...tputs of the sensors and are not controlled by MCU Two BSL308PE dual package PMOS transistors 5 used for powering up the TLE4966G 10 and TLE4966V 1G 12 sensors One PMOS BSS84P 6 used to power up the 3D sensor magnetic probe TLI493D W2BW 11 4 x LEDs for checking visually the sensor output states 7 Mounting hole for lateral placement use case 8 Mounting hole for vertical placement use case 9 GND S2_...

Страница 16: ...Hardware design schematic overview 1 2 16 2020 10 08 Copyright Infineon Technologies AG 2020 All rights reserved ...

Страница 17: ...Hardware design schematic overview 2 2 17 2020 10 08 Copyright Infineon Technologies AG 2020 All rights reserved ...

Страница 18: ...Detailled schematic Power supply 18 2020 10 08 Copyright Infineon Technologies AG 2020 All rights reserved ...

Страница 19: ...Detailled schematic On board Debugger 19 2020 10 08 Copyright Infineon Technologies AG 2020 All rights reserved ...

Страница 20: ...Detailled schematic XMC1100 pins 20 2020 10 08 Copyright Infineon Technologies AG 2020 All rights reserved ...

Страница 21: ...Detailled schematic Probe and PMOS 21 2020 10 08 Copyright Infineon Technologies AG 2020 All rights reserved ...

Страница 22: ...Detailled schematic LEDs and connectors 22 2020 10 08 Copyright Infineon Technologies AG 2020 All rights reserved ...

Страница 23: ...Detailled schematic Hall sensors 23 2020 10 08 Copyright Infineon Technologies AG 2020 All rights reserved ...

Страница 24: ...Hardware design layout Top layout render Bottom layout render 24 2020 10 08 Copyright Infineon Technologies AG 2020 All rights reserved ...

Страница 25: ...Agenda Description Content Use Cases Hardware description design Software Installation Process Software features 1 2 3 4 5 6 25 2020 10 08 Copyright Infineon Technologies AG 2020 All rights reserved ...

Страница 26: ... msi file Make sure you have administrator rights before proceeding The installer is starting up by showing the Welcome section Please note that the software version can change over time with no notification In order to proceed please click Next 26 2020 10 08 Copyright Infineon Technologies AG 2020 All rights reserved ...

Страница 27: ... in this view the user is prompted to read the license agreement and accept it The Next button is only activated after accepting the license agreement by checking the highlighted box 27 2020 10 08 Copyright Infineon Technologies AG 2020 All rights reserved ...

Страница 28: ...NET Framework if not already installed NET version 4 5 or later The Segger JLINK driver has to be at least newer than version V6 56b therefore the installation of Segger driver is mandatory If you are certain that your Jlink Segger driver is newer than V6 56B than you can close the installer pop up launched by Segger Driver Installer 28 2020 10 08 Copyright Infineon Technologies AG 2020 All rights...

Страница 29: ...Evaluation Kit Software Installation 4 6 Confirm view in this view the user shall confirm the installation 29 2020 10 08 Copyright Infineon Technologies AG 2020 All rights reserved ...

Страница 30: ...ccess Control UAC is providing installation permissions therefore administration rights have to be provided Please wait until the installation is finalized Additional installation will be requested by Segger Jlink driver installer 30 2020 10 08 Copyright Infineon Technologies AG 2020 All rights reserved ...

Страница 31: ...ation Kit Software Installation 6 6 Finish view the installation successfully finished Press Finish button for closing the installer 31 2020 10 08 Copyright Infineon Technologies AG 2020 All rights reserved ...

Страница 32: ...Agenda Description Content Use Cases Hardware description design Software Installation Process Software features 1 2 3 4 5 6 32 2020 10 08 Copyright Infineon Technologies AG 2020 All rights reserved ...

Страница 33: ...t menu Infineon Technologies TLE4966 MS2GO Make sure the device is plugged in via micro USB cable One XMC device should be discovered in your Device list Press on the device in order to flash the correct firmware and to start the application 33 2020 10 08 Copyright Infineon Technologies AG 2020 All rights reserved ...

Страница 34: ...G is powered up The GUI will acquire and display the outputs Q1 Direction and Q2 Speed of the lateral sensor synchronized with the 3D magnetic sensor readouts using the Z axis of the magnetic field The readout is started by pressing Start button 34 2020 10 08 Copyright Infineon Technologies AG 2020 All rights reserved ...

Страница 35: ...66V 1G is powered up while the TLE4966G is not The GUI will acquire and display the outputs Q1 Direction and Q2 Speed of the vertical sensor synchronized with the 3D magnetic sensor readouts using the X axis of the magnetic field The readout is started by pressing Start button 35 2020 10 08 Copyright Infineon Technologies AG 2020 All rights reserved ...

Страница 36: ...g the View button A new window will pop out displaying the raw data acquired The user may zoom on the wave All acquired points are visible and a legend will pop up on when the mouse cursor is over the graph The user may save the acquired set of data in CSV format for post processing 36 2020 10 08 Copyright Infineon Technologies AG 2020 All rights reserved ...

Страница 37: ...Evaluation Kit Software GUI Explanatory Further explanation hints can be discovered by pressing the buttons 37 2020 10 08 Copyright Infineon Technologies AG 2020 All rights reserved ...

Страница 38: ......

Отзывы: