background image

TDA7210V Remote Control Rx-Board

 

Step-by-Step Quick Start Guide 

 

Please follow this step-by-step approach when you start up your TDA7210V 
PMAfob remote control demo for the first time: 

„

 

Check the placement of all jumpers on the board. By default the jumpers marked 

MSEL

 and 

CSEL

 must be in closed position. The power down mode selection jumper 

marked 

PWRDWN

 must be closed in position 

+V

. All other jumpers or test pins on 

the board must be left in open position (except the power supply selection jumper 

5V/7-15V

 – see below). See the picture on the right where all closed jumpers are 

marked. 

„

 

Connect the antenna to the SMA-connector marked 

RF IN.

 This application operates 

in the 434 MHz frequency band. Therefore, antennas with red marking are suitable.

 

„

 

Connect a suitable power supply to the TDA7210V Remote Control Rx-Board. There 
are two alternatives:  

„

 

Regulated: Connect a regulated DC supply voltage of +5.0V to the screw 
terminals marked 

GND

 and 

5V

. In this power supply mode the related 

jumper must be placed in position 

5V

.  

„

 

Unregulated: Connect an unregulated DC supply voltage in the range 
between 7.0V and 15.0V to the screw terminals 

GND

 and 

7-15V

. In this 

power supply mode the related jumper must be placed in position 

7-15V

.  

„

 

Switch on the power supply. 

„

 

Press button 

S1

 to activate the receive mode. LEDs 

DL1

 and 

DL2

 will signalize the 

receive-ready state. 

„

 

Upon delivery of the kit the enclosed PMAfob remote controller is already set to the 
correct protocol mode for this demo. By pressing buttons on the PMAfob related 
channel LEDs (

CH1…CH5

) on the TDA7210V Remote Control Rx-Board will change 

their state. 

 
Note: The PMAfob remote controller supports different protocol modes. This demo 
requires the mode 

XTEA-Frame/no encryption 

which is already configured upon 

shipment of the kit. The protocol mode may be changed by removing the battery from 
the PMAfob or accidently by holding buttons down longer than 3 seconds. In case your 
TDA7210V Remote Control Rx-Board does not react to any remote control commands 
anymore, follow these steps to reactivate the right protocol mode: 

„

 

Open the PMAfob housing and remove the battery for longer than 5 seconds. Re-
insert the battery again. 

„

 

Hold down button 

CH5

 for longer than 3 seconds. 

„

 

Hold down button 

CH4

 for longer than 3 seconds. 

„

 

Now, protocol mode 

XTEA-Frame/no encryption

 is re-established and the demo shall 

operate as expected. 

 
Find more information about PMAfob protocol modes in the PMAfob User Guide. 
 
Early versions of PMAfob delivered with other kits may not support the protocol mode 

XTEA-Frame/no encryption

. These may be re-programmed with newest PMAfob 

firmware (see 

www.infineon.com/PMAfob

) for full compatibility with all applications. 

Quick Start 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
Antenna Colour Coding 

 

„

 

Green:   315 MHz 

„

 

Red:      434MHz 

„

 

White:    868 MHz 

„

 

Yellow:   915 MHz 

 

2010

 