Table 25
Event response mapping – voltage rails (continued)
Event
Move to
FAULT
Move to
ACTIVE;
Generate RESET
Move to
DISABLED
No transition;
Generate interrupt
Boost1: UV
–
–
–
X
Boost1: StG
X
–
–
–
VM1
VM1: OV
X
–
–
–
VM1: UV
–
X
–
–
VM1: StG
X
–
–
–
VM2
VM2: OV
–
–
–
X
VM2: UV
–
–
–
X
VM2: StG
–
–
–
X
Table 26
Event response mapping – other events
Event
Move to
FAULT
Move to
ACTIVE;
Generate
RESET
Move to
DISABLED
No transition;
Generate
interrupt
WWD: counter increase
–
–
–
X
WWD: counter overflow
–
X
–
–
INIT timer expired – first time
–
X
–
–
INIT timer expired – second time
X
–
–
–
–
–
–
–
–
Internal protection: band gap warning
–
–
–
X
Internal protection: band gap fault
X
–
–
–
IOVDD: OV
X
–
–
–
IOVDD: UV
–
X
–
–
IOVDD: StG
X
–
–
–
Internal protection: internal supplies
(UV,OV)
–
–
–
–
–
–
–
–
Buck1: OT warning
–
–
–
X
Buck1: OT fault
X
–
–
–
26
If the TLF30681QVS01 detects an UV or OV fault condition on the internal supplies, then it turns off
completely. The TLF30681QVS01 enters the ACTIVE state when the UV or OV condition is no longer
present.
OPTIREG
™
PMIC TLF30681QVS01
Power management IC
State machine
Datasheet
82
Rev. 1.0
2020-04-08