Infineon MicroIAS Скачать руководство пользователя страница 2

 

 

 

2 of 5 

  

 

 

V1.5 

Infineon Alarm System – Quick Start Guide 

1

 

MicroIAS 

Infineon’s MicroIAS is a small form-factor board (Figure 1) designed for the use as sensor fusion based alarm 
system. It employs a high accuracy pressure sensor (PS), a microphone (MIC) with high SNR and a powerful small 
form-factor ARM M4F core microcontroller from Quicklogic that processes sensor data from the microphone 
(listens to glass break) and the pressure sensor (picks up changes in  barometric pressure after a glass break 
happens) and runs sensor fusion algorithms to trigger an alarm. 

The MicroIAS board allows a software developer access to all essential interfaces such as UART,  SWD (CON1 
connector for development and debug), power supply, a manual reset (SW1) and it provides visual aids (LED1 
and LED2) for the user to identify power applied (LED1 = green) and alarm triggered (LED2 = red; blinks once for 
intruder an twice for glass break).  

An external power supply with a 3.6V to 6V range must be applied between GND and VCC on CON2 via a small 2-
pin micro-cable (included) to produce the board’s needed power supply (Figure 2). LED1 (green), will be lit when 
the board has received the needed supply. The voltage is routed through a small LDO to generate the 1.8V needed 
to power sensors (MIC and PS) as well as SPI Flash and MCU. 

 

Figure 1 

MicroIAS form-factor board – top/bottom view 

 

 

Figure 2 

MicroIAS form-factor board connections 

Содержание MicroIAS

Страница 1: ...t Guide About this document Scope and purpose The document is the Quick Start Guide for Infineon s Micro IAS It contains information pertaining to the setup and usage of the MicroIAS Intended audience Customers interested in evaluating the MicroIAS Table of Contents About this document 1 Table of Contents 1 1 MicroIAS 2 2 Start up procedure 3 2 1 Connecting the MicroIAS 3 Revision history 4 ...

Страница 2: ...re developer access to all essential interfaces such as UART SWD CON1 connector for development and debug power supply a manual reset SW1 and it provides visual aids LED1 and LED2 for the user to identify power applied LED1 green and alarm triggered LED2 red blinks once for intruder an twice for glass break An external power supply with a 3 6V to 6V range must be applied between GND and VCC on CON...

Страница 3: ...via the matching black red wire pair with receptacle included in the MicroIAS evaluation kit package A battery pack lab power supply or power bank producing a clean 5V output voltage will suffice Connect the red wire to 5V do not exceed 6V as 6V power supplies may damage the on board LDO used to generate the 1 8V for the sensors and the MCU and the black wire to the ground of your power source Onc...

Страница 4: ...19 Updated connectivity text section to ensure IO19 and IO20 are shunted correctly for proper functionality 1 2 2 27 2020 Updated pin labeling in Figure 2 1 3 3 2 2020 Added reset procedure after power up in Section 2 1 4 9 15 2020 Restructuring of figures to reflect latest updates of layout and connectivity updates to start up procedure section in this document 1 5 11 28 2020 Updated connectivity...

Страница 5: ...s in customer s applications The data contained in this document is exclusively intended for technically trained staff It is the responsibility of customer s technical departments to evaluate the suitability of the product for the intended application and the completeness of the product information given in this document with respect to such application For further information on the product techn...