User Manual
31
V 1.1
2022-09-12
User manual for MERUS™ audio amplifier configurato
r
MA2304DNS/MA2304PNS
DSP audio blocks
Table 6
Parametric EQ filter controls
Control name
Description
Min.
Default
Max.
Unit
Filter subtype
Analog filter prototypes
Frequency
Low-pass/high-pass cut-off (f
c
)
frequency
10
1000
F
s
/2
Hz
Q-value
1
Filter quality factor. Affects frequency
response and damping in time domain.
0.5
1
10.0
1
Q-
value only available in “2nd order custom” subtype.
Below is an example measurement of a second-order Linkwitz-Riley filter crossover:
Figure 43
Second-order Linkwitz-Riley filters, f
c
= 300 Hz, left channel blue, right channel red