User Guide
19 of 26
002-34123 Rev. **
2021-10-21
CY4534 EZ-
PD™ barrel connector replacement
-plus (BCR-PLUS)
evaluation kit guide
Kit operation
Figure 15
Read existing configuration parameters
7.
The existing configuration parameters will be displayed. Before proceeding further, save this default
configuration on your PC so that you can reload it once you are done with this demo.
8.
In the panel on the left of the EZ-PD
™ configuration utility window, select
CCGx Configuration
>
BCR
configuration
as shown in
. In the
Power Selection
option on the right-side panel, use the
dropdown menu and
change the option from “
Use BCR pins
” to “
Use configuration table
” as
shown in
. This option allows the users to override the VBUS_MAX, VBUS_MIN, ISNK_COARSE and ISNK_FINE
values set using the rotary switch SW1 or the resistor dividers and use the sink PDOs set in the configuration
table using the EZ-PD
™
configuration utility.
Figure 16
Changing the power selection to “Use configuration table”
9.
Select
CCGx Configuration
>
PDO
>
Sink PDO
and remove the
Sink PDO 1
from the configuration table by
clicking on the
Remove
button as shown in