![Infineon Technologies XC2200 Скачать руководство пользователя страница 598](http://html1.mh-extra.com/html/infineon-technologies/xc2200/xc2200_user-manual_2055439598.webp)
XC2200 Derivatives
System Units (Vol. 1 of 2)
The External Bus Controller EBC
User’s Manual
9-14
V2.1, 2008-08
EBC_X8, V1.0d1
9.3.2
The EBC Mode Register 0
EBCMODe Register 0
EBCMOD0
EBC Mode Register 0
XSFR (EE00
H
/--)
Reset Value: 5000
H
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0
RDY
POL
RDY
DIS
ALE
DIS
BYT
DIS
WR
CFG
EBC
DIS
SLA
VE
ARB
EN
CSPEN
SAPEN
rw
rw
rw
rw
rw
rw
rw
rw
rw
rw
Field
Bits
Type
Description
RDYPOL
15
rw
READY Pin Polarity
1)
0
B
READY is active low
1
B
READY is active high
RDYDIS
14
rw
READY Pin Disable
0
B
READY enabled
1
B
READY disabled
ALEDIS
13
rw
ALE Pin Disable
0
B
ALE enabled
1
B
ALE disabled
BYTDIS
12
rw
BHE Pin Disable
0
B
BHE enabled
1
B
BHE disabled
WRCFG
2)
11
rw
Configuration for Pins WR/WRL, BHE/WRH
0
B
WR and BHE
1
B
WRL and WRH
EBCDIS
10
rw
EBC Pins Disable
0
B
EBC is using the pins for external bus
1
B
EBC pins disabled
SLAVE
9
rw
SLAVE Mode Enable
0
B
Bus arbiter acts in master mode
1
B
Bus arbiter acts in slave mode
ARBEN
8
rw
BUS Arbitration Pins Enable
0
B
HOLD, HLDA and BREQ pins are disabled
1
B
Pins act as HOLD, HLDA, and BREQ