TC1796
Peripheral Units (Vol. 2 of 2)
Analog-to-Digital Converter (ADC)
User’s Manual
25-68
V2.0, 2007-07
ADC, V2.0
TCRP
Timer Conversion Request Pending Register
(1B8
H
)
Reset Value: 0000 0000
H
31
30
29
28
27
26
25
24
23
22
21
20
19
18
17
16
0
r
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0
TRP
15
TRP
14
TRP
13
TRP
12
TRP
11
TRP
10
TRP
9
TRP
8
TRP
7
TRP
6
TRP
5
TRP
4
TRP
3
TRP
2
TRP
1
TRP
0
rh
rh
rh
rh
rh
rh
rh
rh
rh
rh
rh
rh
rh
rh
rh
rh
Field
Bits
Type Description
TRPn
(n = 0-15)
n
rh
Timer Conversion Request Pending Flag for
Channel n
A pending flag TRPn is set each time a conversion
request is generated for channel n on timer underflow
that could not be serviced immediately. A start of
conversion of the pending request leads
automatically to a cleared of the pending flag. All
pending request flags can also be cleared under
software control, if bit AP.TP is cleared.
0
B
No timer based conversion request is pending
for channel n
1
B
A timer based conversion request is pending for
channel n
0
[31:16] r
Reserved
Read as 0.