TC1796
Peripheral Units (Vol. 2 of 2)
Micro Link Interface (MLI)
User’s Manual
23-57
V2.0, 2007-07
MLI, V2.0
Note: The number of SRx outputs of an MLI module and their connection to other
modules depends on the implementation of the MLI module in the specific product.
23.2.5
Transmitter Events
The MLI transmitter can generate the following MLI events:
Table 23-7
MLI Transmitter Events
Events
Events combined to
See
Parity Error
Parity/Time-out Error
Time-out Error
Normal Frame Sent in Pipe 0
Normal Frame Sent in Pipe 0
Normal Frame Sent in Pipe 1
Normal Frame Sent in Pipe 1
Normal Frame Sent in Pipe 2
Normal Frame Sent in Pipe 2
Normal Frame Sent in Pipe 3
Normal Frame Sent in Pipe 3
Command Frame Sent in Pipe 0
Command Frame Sent
Command Frame Sent in Pipe 1
Command Frame Sent in Pipe 2
Command Frame Sent in Pipe 3