TC1784
On-Chip System Buses and Bus Bridges
User´s Manual
4-59
V1.1, 2011-05
Buses, V1.9
4.7
On Chip Bus Master TAG Assignments
Each master interface on the FPI Bus and on the LMB Bus is assigned to a 4-bit
(FPI Bus) or 3-bit (LMB Bus) identification number, the master TAG number (see
). This makes it possible for software debug and MCDS purposes to
distinguish which master has performed the current transaction (see
1)
and
1) Pls. note that the TAG bit field in the register
represents only bit 0-2 of the
TAG-Number as the TAG number of all On Chip Bus master interfaces connected to LMB is 0.
Table 4-15
On Chip Bus Master TAG Assignments
TAG-Number Module
Location Description
0000
B
LFI
LMB
LFI Master Interface to LMB
0001
B
-
-
Reserved
0010
B
PMI
LMB
Program Memory Interface
0011
B
-
-
Reserved
0100
B
DMI
LMB
Data Memory Interface
0101
B
-
-
Reserved
0110
B
-
-
Reserved
0111
B
DMA
LMB
DMA Controller Master Interface on LMB
1000
B
-
-
Reserved
1001
B
PCP
SPB
Peripheral Control Processor
1010
B
DMA
SPB
DMA Controller Master Interface on SPB
1011
B
LFI
SPB
LFI Master Interface to SPB
1100
B
-
-
Reserved
1101
B
-
-
Reserved
1110
B
-
-
Reserved
1111
B
-
-
Reserved
Содержание TC1784
Страница 1: ...User s Manual V1 1 2011 05 Microcontrollers TC1784 32 Bit Single Chip Microcontroller ...
Страница 3: ...User s Manual V1 1 2011 05 Microcontrollers TC1784 32 Bit Single Chip Microcontroller ...
Страница 950: ...TC1784 Direct Memory Access Controller DMA User s Manual 11 132 V1 1 2011 05 DMA V3 03 ...
Страница 1949: ...TC1784 General Purpose Timer Array GPTA v5 User s Manual 21 297 V1 1 2011 05 GPTA v5 V1 14 ...
Страница 2350: ...w w w i n f i n e o n c o m Published by Infineon Technologies AG Doc_Number ...