FPITAG
[19:16] rh
FPI Bus Master TAG Status
This bit field indicates the master TAG captured from
the FPI Bus signal lines when the BCU break trigger
event occurred (see
). The master TAG
identifies the master of the transfer which generated
BCU break trigger event.
0
15,
[31:20]
rh
Reserved
Read as 0; should be written with 0.
SBCU_DBDAT
SBCU Debug Data Status Register
(050
H
)
Reset Value: 0000 0000
H
31
0
FPIDATA
rh
Field
Bits
Type Description
FPIDATA
[31:0]
rh
FPI Bus Data Status
This register contains the FPI Bus data that was
captured when the OCDS break trigger event
occurred.
Field
Bits
Type Description