9
Troubleshooting
WARNING
Substitution of components may impair intrinsic safety.
Except for the batteries and the sensor, the internal parts of the GAS-Mate
Combustible Gas Leak Detector are not user serviceable. If you experience a
problem with your GAS-Mate, follow the steps in the trouble shooting guide below
to determine how to remedy your problem. If you cannot remedy the problem, take
your GAS-Mate to your wholesaler for warranty evaluation or call our technical
assistance line at +49 221 56788-660.
Problem
Possible Cause
Remedy
GAS-Mate will not power
up.
Batteries are worn out.
Replace batteries.
Batteries are improperly
installed.
Refer to
for
proper installation.
Poor sensitivity. Unit
powers up, but has a
difficult time detecting
combustible gas.
Unit set to low sensitivity.
Increase sensitivity by
dragging finger upwards
on touch pad.
Sensor is worn out and
needs to be replaced.
Replace sensor.
Alarm sounds
continuously, even after
a couple minutes of
warm-up.
The sensor is not
installed properly or is
missing.
The sensor leads must
be straight and inserted
in the holes at the base
of the sensor socket. Or,
the orientation tab is not
properly aligned in the
probe tip. Refer to
Sensor is worn out and
needs to be replaced.
Replace sensor.