10

Unobstructed Sunlight 

Solar panels function through the interaction of many individual 
cells. Keeping this in mind, solar results can be greatly affected 
with even the slightest obstruction to a single cell of the pan-
el.  When selecting a location for panel placement, keep this in 
mind. Make sure the panel is free of any debris, or any shadows 
created by things like tree branches, overhead structures, or any 
other objects in the environment.

Safety Tips

The Apex is designed for use with Inergy branded solar panels.  
These solar panels will provide the best experience possible.  As 
a hard rule - all solar panels must be connected to the Apex (and 
to each other) in a PARALLEL wiring configuration.  Inergy solar 
panels are designed in this way.

EXTERNAL BATTERY GUIDELINES

The Apex was designed with user customization in mind, in an 
effort to expand the number of applications and versatility of 
the system. External batteries are one of the main ways we have 
done this. Below are some guidelines for expanding the power of 
the Apex through additional batteries, as well as some import-
ant safety tips.

Connecting Batteries

Before external batteries are connected, they must be balanced 
to match the Voltage of the Apex.  Discharge the Apex to 10.5 
Volts prior to connecting any external batteries.  Similarly, 

ALL 

EXTERNAL BATTERIES MUST BE WITHIN 0.1 VOLTS OF APEX 
VOLTAGE (10.4 VOLTS - 10.6 VOLTS) BEFORE CONNECTING.

FAILURE TO DO SO VOIDS THE WARRANTY AND CAN RESULT 
IN IRREPARABLE DAMAGE TO THE APEX AND/OR RISK OF 
FIRE.

External batteries should be connected in a PARALLEL wiring 
configuration to expand the battery capacity of the Apex (see 
page 13 for more information).  This is done by connecting 
positive to positive, and negative to negative.  This is the only 
approved method for expanding battery capacity, any deviation 
can result in severe damage to the Apex and create a potentially 
dangerous situation.  It will also void any and all warranties.

Battery wires & connectors:

 

 When connecting external 

batteries to the Apex, we recommend using 2/0 Gauge battery 
cables (made of pure copper, NOT copper plated) with 3/8” ring 
terminals for up to a 5 foot long cable.  Call our technical sup-
port for questions about longer lengths at 

(877) 891-2657.

Number of Batteries

“How many batteries can I connect to the Apex?” 

In general, we recommend connecting no more than 3,000 Watt 
Hours (238 Ah, 12.6V) of external batteries for best results.  Re-
member, the maximum charge input of the Apex remains steady 
at 500 Watts.  The more batteries that are connected, the lon-
ger they all take to charge.

Types of Batteries

“What types of batteries can I connect to the Apex?” 

Any 12 Volt Deep Cycle Lead Acid, AGM, or Gel Cell battery can be 
connected to the Apex.  DO NOT connect external lithium batter-
ies not supplied by Inergy. Irreparable damage to the Apex or 
fire could result.

Содержание APEX

Страница 1: ...APEX USER MANUAL POWERFORLIFE ...

Страница 2: ... to a full year however we recommend checking the battery level every 3 months to ensure it is over 10 charged Q Can I use the Apex while it is charging A Yes It s capable of outputting power while charging Q Can I fly on an airplane with the Apex or ship it myself A No The Apex cannot be carried on or checked onto passenger aircraft Similarly due to the size of the internal lithium battery shippi...

Страница 3: ... is charging and the Wattage figure on the top right will display the charge rate in Watts Charging with Solar Panel s Charge times vary depending on solar panels used sun condi tions and angle of panel s relative to the sun If using third party panels not supplied by Inergy always connect panels in a PARALLEL wiring configuration not a SERIES wiring configu ration See PAGE 8 Solar Energy General ...

Страница 4: ...t was under stress They are labeled as AC DC 1 and DC 2 Simply reset the breaker by allowing it to cool for several min utes then press it back into place Reduce the power demand on the Apex and you re good to go Reading the LCD Display The LCD Display is activated by the power switch in both DC mode DC ONLY or AC DC mode ALL ON A fully charged Apex will be between 12 3 12 6 Volts A completely dis...

Страница 5: ...ut 12 5 Amps 3 000 Watt starting surge maximum Connector Type Nema TT 30R F 12V DC Sockets 180 Watts 15 Amps maximum continuous output per socket G USB Ports USB C PD 5V 3A 9V 2A 12V 1 5A USB A QC 3 0 5V 3A 9V 2A 12V 1 5A NOTE For full quick charge or power delivery performance the Apex battery must be charged over 12 Volts H Basecamp LED Light Ports 12V DC output Connect up to 10 Base camp LED Li...

Страница 6: ...general rule of thumb the brighter the sun is shining and the clearer the day the better solar panels will work Panels op erate at peak efficiency when the sun is most direct typically around midday Solar panels run off of light not heat In fact solar panels pro duce the most during cold clear days rather than in extremely hot conditions Even during windy or rainy conditions they are able to funct...

Страница 7: ...TTERIES MUST BE WITHIN 0 1 VOLTS OF APEX VOLTAGE 10 4 VOLTS 10 6 VOLTS BEFORE CONNECTING FAILURE TO DO SO VOIDS THE WARRANTY AND CAN RESULT IN IRREPARABLE DAMAGE TO THE APEX AND OR RISK OF FIRE External batteries should be connected in a PARALLEL wiring configuration to expand the battery capacity of the Apex see page 13 for more information This is done by connecting positive to positive and nega...

Страница 8: ...nect an external battery ensure the external battery measures between 10 4 10 6 Volts before it is connected A Voltage meter available at local hardware or auto parts store can be used to measure your external batteries IMPORTANT NOTICE REGARDING LITHIUM BATTERIES In general devices with large quantities of lithium ion batteries like the Apex should be stored similar to a gas powered gen erator aw...

Страница 9: ...rkmanship and material under normal consumer use during the applicable warranty period identified in Paragraph 2 below subject to the exclusions set forth in Paragraph 6 below This warranty statement sets forth INER GY SOLAR s total and exclusive warranty obligation We will not assume nor authorize any person to assume for us any other liability in connection with the sales of our products WARRANT...

Страница 10: ...880 N 5th Ave Pocatello ID 83201 INFO INERGYSOLAR COM 877 891 2657 POWERFORLIFE ...

Отзывы: