iNels RFSC-61 Скачать руководство пользователя страница 6

02-62/2016 Rev.4

RFSC-61

Switching socket

EN

Made in Czech Republic

6/6

Technical parameters /

S

upp

l

y

 

vo

l

ta

g

e

A

pparent

 

po

w

er

Dissipated

 

po

w

er

S

upp

l

y

 

vo

l

ta

g

e

 

to

l

erance

O

utput

 

N

umber

 

o

contacts

R

ated

 

current

Sw

itchin

po

w

er

P

eak

 

current

Sw

itchin

vo

l

ta

g

e

M

in.

 

s

w

itchin

po

w

er

 

DC

M

echanica

service

 l

i

f

e

El

ectrica

service

 l

i

f

e

 (A

C1

): 

Contro

RF 

command

 f

rom

 

the

 

transmitter

M

anua

contro

l: 

R

an

g

e

 

in

 

open

 

space

O

ther

 

data

O

peratin

temperature

W

orkin

position

M

ountin

g: 

P

rotection

O

vervo

l

ta

g

e

 

cate

g

ory

Contamination

 

de

g

ree

Dimensions

W

ei

g

ht

R

e

l

ated

 

standards

Attention:
When you instal iNELS RF Control system, you have to keep minimal 
distance 1 cm between each units.
Between the individual commands must be an interval of at least 1s.

             RFSC-61/230V                             RFSC-61/120V

Selecting the memory function /

• Memory function on: 

- For functions 1-4, these are used to store the last state of the relay output before the supply 

voltage drops, the change of state of the output to the memory is recorded 15 seconds after 
the change.

- For functions 5-6, the target state of the relay is immediately entered into the memory after the 

delay, after re-connecting the power, the relay is set to the target state.

• Memory function off:

When the power supply is reconnected, the relay remains off.

1

2

Press of programming button on receiver RFSC-61 for 1 second 
will activate receiver RFSC-61 into programming mode. LED is 
fl ashing in 1s interval.

Pressing the programming button on the RFSC-61 receiver for less 
than 1 second will fi nish the programming mode, this will reverse 
the memory function. The LED lights up according to the current 
pre-set memory function. The set memory function is saved.
Every other change is made in the same way.

PROG

1s

1 x

PROG

1s

1 x

Instruction manual is designated for mounting and also for user of the device. It is always a part of its packing. Instal-
lation and connection can be carried out only by a person with adequate professional qualifi cation upon under-
standing this instruction manual and functions of the device, and while observing all valid regulations. Trouble-free 
function of the device also depends on transportation, storing and handling. In case you notice any sign of damage, 
deformation, malfunction or missing part, do not install this device and return it to its seller. It is necessary to treat 
this product and its parts as electronic waste after its lifetime is terminated.  Before starting installation, make sure 
that all wires, connected parts or terminals are de-energized. While mounting and servicing observe safety regula-
tions, norms, directives and professional, and export regulations for working with electrical devices. Do not touch 
parts of the device that are energized – life threat.  Due to transmissivity of RF signal, observe correct location of 
RF components in a building where the installation is taking place. RF Control is designated only for mounting in 
interiors. Devices are not designated for installation into exteriors and humid spaces. The must not be installed into 
metal switchboards and into plastic switchboards with metal door – transmissivity of RF signal is then impossible.  
RF Control is not recommended for pulleys etc. – radiofrequency signal can be shielded by an obstruction, inter-
fered, battery of the transceiver can get fl at etc. and thus disable remote control. 

Warning

DE

Schaltbare Steckdose

AT

 www.elkoep.com / www.elkoep.de / www.elkoep.at

ELKO EP, s.r.o. | Palackého 493 | 769 01 Holešov, Všetuly | Czech Republic | e-mail: [email protected] | Support: +420 778 427 366

ELKO EP Germany GmbH | Minoritenstr. 7 | 50667 Köln | Deutschland | E-mail: [email protected] | Tel: +49 (0) 221 222 837 80 

ELKO EP Austria GmbH | Laurenzgasse 10/7 | 1050 Wien | Österreich | E-mail: [email protected] | Tel: +43 (0) 676 942 9314

Technische Parameter 

S

pannun

g

sversor

g

un

g: 

S

chein

l

eistun

g: 

Ver

l

ust

l

eistun

g: 

T

o

l

eranz

 S

pannun

g

sversor

g

un

g: 

A

us

g

an

g

A

nzah

der

 

Kontakte

:

M

essstrom

S

cha

l

t

l

eistun

g: 

S

pitzenstrom

S

cha

l

tspannun

g: 

M

in.

 S

cha

l

t

l

eistun

DC

M

echanische

 L

ebensdauer

El

ectrische

 L

ebensdauer

 (A

C1

): 

S

teuerun

g

RF S

i

g

na

l ü

ber

 S

ender

M

anue

ll

e

 S

teuerun

g: 

R

eich

w

eite

 

im

 F

reien

A

ndere

 

Daten

A

rbeitstemperatur

E

inbauposition

I

nsta

ll

ation

S

chutzk

l

asse

:

Kate

g

orie

 Ü

berspannun

g: 

Verschmutzun

g

s

g

rad

A

bmessun

g

en

G

e

w

icht

S

tandards

             

2

3

0

 

-

 

250V

 / 

50-60

H

z

                                 

120

 

V

 A

C

 / 

60

H

z

 

6

 

V

0.

7 W

+

10

 

%

-15

 

%

1

s

w

itchin

g / S

cha

l

tkontakt

 (AgS

n

O

2

)

16

 A / A

C1

4

000

 

V

A / A

C1

, 3

8

4 W / 

DC

3

0

 A / < 3 

s

250

 

V

 A

C1

 / 

2

V

 

DC

500

 

m

W

3x

10

7

0.

7x

10

5

866

 MH

z

868

 MH

z

916

 MH

z

button

 / T

aste

 PROG (ON/OFF)

up

 

to

 / 

bis

 

zu

 

200

 

m

-15

 

...

 + 

50

 °

C

any

 / 

be

l

iebi

g

p

l

u

into

 

a

 

socket

 / E

instecken

 

in

 

die

 S

teckdose

 

IP3

0

III

.

2

60

 x 

120

 x 

80

 

mm

195

 g

EN 

60669

, EN 3

00220

, EN 3

01

4

89

 R&TTE 

Directive

, O

rder.

 N

o

 4

26

/

2000

 

Co

ll

.

 (

Directive

 

1999

/E

C

) /

EN 

60669

, EN 3

00220

, EN 3

01

4

89

 R

icht

l

inie

 RTTE, RG N

r.

4

26

/

2000

 Sgl

.

 (R

icht

l

inie

 

1999

/EG)

Achtung:
Bei der Installation Aktoren iNELS RF Control muss es der Mindestab-
stand 1 cm geachtet sein.
Zwischen aufeinanderfolgenden Befehlseingaben sollte mindesten 1 s 
Abstand liegen.

Die Betriebsanleitung dient der Montage, sowie dem Benutzer des Geräts. Sie ist immer im Lieferumfang enthalten. 
Die Montage und der Anschluss darf nur durch eine Person mit einer angemessenen Berufsqualifi kation, nach die-
ser Bedienungsanleitung und Funktionen des Gerätes und unter Beachtung aller gültigen Vorschriften ausgeführt 
werden. Die störungsfreie Funktion des Gerätes hängt auch von Transport, Lagerung und Handhabung ab. Falls Sie 
irgendwelche Anzeichen von Beschädigung, Verformung, Fehlfunktionen oder Fehlteilen feststellen, ie das Gerät 
nicht und wenden sich an den Verkäufer. Es ist notwendig, dieses Produkt und Teile davon als Elektronikschrott 
zu behandeln, nachdem seine Lebensdauer beendet ist. Vor Beginn der Montage ist sicherzustellen, dass alle 
Leitungen, miteinander verbundenen Teilen oder Anschlüsse spannungsfrei sind. Während der Montage und der 
Wartung sind die Sicherheitsvorschriften, Normen, Richtlinien für die Arbeit mit elektrischen Geräten zu beachten. 
Berühren Sie keine Teile des Gerätes, die mit Energie versorgt werden - Lebensgefahr. Aufgrund der Sendeleistung 
des RF-Signals, beachten Sie den geeigneten Montageort der RF-Komponenten in einem Gebäude, in dem die Ins-
tallation stattfi ndet. RF Control ist nur für die Montage im Innenbereich geeignet. Geräte sind nicht für die Montage 
in Außenbereichen und Feuchträumen geeignet. RF Control Komponenten dürfen nicht in Metallschalttafeln und 
in Kunststoff  -Schalttafeln mit Metalltür installiert werden - Die Durchlässigkeit des RF-Signals ist dann nicht gege-
ben. RF Control ist nicht für Aufzüge geeignet - das RF Signal kann gestört und abgeschirmt werden, die Batterie 
des Emfängers verliert schnell die Leistung etc. - dieses verhindert die Steuerung durch eine Steuerungseinheit.

Warnung

Auswählen einer Speicherfunktion 

• Speicherfunktion an:

- Für die Funktionen 1-4 wird es verwendet, um den letzten Zustand des Relaisausgangs vor 

dem Netzausfall zu speichern, wobei der Zustand des Ausgangssignals in den Speicher nach 
15 s aus der Änderung geschrieben wird.

- Bei den Funktionen 5-6 wird der Zielzustand des Relais sofort nach Ablauf der Verzögerung in 

den Speicher eingegeben, nach erneutem Verbinden der Stromversorgung wird das Relais 
auf den Zielzustand gesetzt.

• Speicherfunktion aus:

Wenn die Stromversorgung wieder angeschlossen ist, bleibt das Relais ausgeschaltet.

Drücken der Programmiertaste am Empfänger RFSC-61 für 1 Se-
kunde aktiviert den Programmiermodus des Empfängers RFSA-
x1B  LED blinkt im 1s-Intervall.

Die Programmierung beendet die Programmiertaste auf RFSC-61, 
weniger als 1 Sekunde, wodurch die Speicherfunktion auf das Ge-
genteil geändert wird. Die LED leuchtet entsprechend der aktuell 
eingestellten Speicherfunktion. Die gespeicherte Speicherfunkti-
on wird gespeichert.
Jede andere Veränderung wird in gleicher Weise gemacht.

Отзывы: