02-56/2016 Rev.5
RFSAI-61B
Wireless switch unit with the input
EN
Made in Czech Republic
↯
Technical parameters /
S
upp
l
y
vo
l
ta
g
e
:
A
pparent
po
w
er
:
Dissipated
po
w
er
:
S
upp
l
y
vo
l
ta
g
e
to
l
erance
:
O
utput
N
umber
o
f
contacts
:
R
ated
current
:
Sw
itchin
g
po
w
er
:
P
eak
current
:
Sw
itchin
g
vo
l
ta
g
e
:
M
in.
s
w
itchin
g
po
w
er
DC
:
M
echanica
l
service
l
i
f
e
:
El
ectrica
l
service
l
i
f
e
(A
C1
):
Contro
ll
in
g
RF
command
f
rom
the
transmitter
:
M
anua
l
contro
l:
Ex
terna
l
button
:
R
an
g
e
in
open
space
:
O
ther
data
Vo
l
ta
g
e
o
f
open
contact
:
R
esist.
o
f
connection
f
or
c
l
osed
contact
:
R
esist.
o
f
connection
f
or
open
contact
:
G
a
l
vanic
iso
l
ation
o
f
input
:
O
peratin
g
temperature
:
W
orkin
g
position
:
M
ountin
g:
P
rotection
:
O
vervo
l
ta
g
e
cate
g
ory
:
Contamination
de
g
ree
:
T
ermina
l
s
(
C
Y w
ire
,
Cross-section
):
T
ermina
l l
en
g
th
:
Dimensions
:
W
ei
g
ht
:
R
e
l
ated
standards
:
Control button input is at the supply voltage potential.
Warning
Instruction manual is designated for mounting and also for user of the device. It is always a part of its packing. Instal-
lation and connection can be carried out only by a person with adequate professional qualifi cation upon under-
standing this instruction manual and functions of the device, and while observing all valid regulations. Trouble-free
function of the device also depends on transportation, storing and handling. In case you notice any sign of damage,
deformation, malfunction or missing part, do not install this device and return it to its seller. It is necessary to treat
this product and its parts as electronic waste after its lifetime is terminated. Before starting installation, make sure
that all wires, connected parts or terminals are de-energized. While mounting and servicing observe safety regula-
tions, norms, directives and professional, and export regulations for working with electrical devices. Do not touch
parts of the device that are energized – life threat. Due to transmissivity of RF signal, observe correct location of
RF components in a building where the installation is taking place. RF Control is designated only for mounting in
interiors. Devices are not designated for installation into exteriors and humid spaces. The must not be installed into
metal switchboards and into plastic switchboards with metal door – transmissivity of RF signal is then impossible.
RF Control is not recommended for pulleys etc. – radiofrequency signal can be shielded by an obstruction, inter-
fered, battery of the transceiver can get fl at etc. and thus disable remote control.
↯
Attention:
When you instal iNELS RF Control system, you have to keep minimal distance 1 cm between each units.
Between the individual commands must be an interval of at least 1s.
RFSAI-61B/230V RFSAI-61B/120V RFSAI-61B/24V
6/6
DE
Funkgesteuerte Schalteinheit mit einem Eingang
AT
www.elkoep.com / www.elkoep.de / www.elkoep.at
ELKO EP, s.r.o. | Palackého 493 | 769 01 Holešov, Všetuly | Czech Republic | e-mail: [email protected] | Support: +420 778 427 366
ELKO EP Germany GmbH | Minoritenstr. 7 | 50667 Köln | Deutschland | E-mail: [email protected] | Tel: +49 (0) 221 222 837 80
ELKO EP Austria GmbH | Laurenzgasse 10/7 | 1050 Wien | Österreich | E-mail: [email protected] | Tel: +43 (0) 676 942 9314
2
3
0
V
A
C
/
50
-
60
H
z
120
V
A
C
/
60
H
z
12-2
4
V
A
C
/
DC
50-60
H
z
7
V
A /
cos
φ =
0.1
7
V
A /
cos
φ =
0.1
-
0.
7 W
0.
7 W
0.
7 W
+
10
%
;
-15
%
1
x
s
w
itchin
g / S
cha
l
tkontakt
(AgS
n
O
2
)
16
A / A
C1
4
000
V
A / A
C1
, 3
8
4 W /
DC
3
0
A / < 3
s
250
V
A
C1
/
2
4
V
DC
500
m
W
3x
10
7
0.
7x
10
5
866
MH
z
,
868
MH
z
,
916
MH
z
button
PROG / T
aste
PROG (ON/OFF)
ma
x
.
12
m
cab
l
e
/
Kabe
l
up
to
/
bis
zu
200
m
3
V
<
1
k
Ω
>
10
k
Ω
↯
no
/
nein
-15
...
+
50
°
C
any
/
be
l
iebi
g
f
ree
at
l
ead-in
w
ires
/ F
rei
an
den
A
nsch
l
ussdr
ä
hten
IP3
0
III
.
2
2
x
0.
7
5
mm
2
,
2
x
2.5
mm
2
90
mm
4
9
x 4
9
x
21
mm
4
6
g
EN
60669
, EN 3
00220
, EN 3
01
4
89
R&TTE
Directive
, O
rder.
N
o
4
26
/
2000
Co
ll
.
(
Directive
1999
/E
C
)/
EN
60669
, EN 3
00220
, EN 3
01
4
89
R
icht
l
inie
RTTE, RG N
r.
4
26
/
2000
Sgl
.
(R
icht
l
inie
1999
/EG)
Technische Parameters
S
pannun
g
sversor
g
un
g:
S
chein
l
eistun
g:
Ver
l
ust
l
eistun
g:
T
o
l
eranz
Versor
g
un
g
sspannun
g:
A
us
g
an
g
A
nzah
l
der
Kontakte
:
M
essstrom
:
S
cha
l
t
l
eistun
g:
S
pitzenstrom
:
S
cha
l
tspannun
g:
M
in.
S
cha
l
t
l
eistun
g
DC
:
M
echanische
L
ebensdauer
:
El
ectrische
l
ebensdauer
(A
C1
):
S
teuerun
g
RF S
i
g
na
l
e
der
S
ender
:
M
anue
ll
e
S
teuerun
gl:
Ex
terne
S
cha
l
ter
:
R
eich
w
eite
im
F
reien
:
A
ndere
Daten
S
pannun
g
am
o
ff
enen
Kontakt
:
W
iderstand
am
g
esch
l
ossenen
Kontakt
:
W
iderstand
am
g
e
öff
neten
Kontakt
:
G
a
l
vanische
A
bschirmun
g
am
E
in
g
an
g:
A
rbeitstemperatur
:
A
rbeitsposition
:
I
nsta
ll
ation
:
S
chutzart
:
Kate
g
orie
Ü
berspannun
g:
Verschmutzun
g
s
g
rad
:
A
nsch
lü
sse
(
C
Y
Draht
, Q
uerschnitt
):
T
ermina
l Lä
n
g
e
:
A
bmessun
g
en
:
G
e
w
icht
:
S
tandards
:
Steuertaste Eingang auf dem potential Versorgungsspannungs.
Warnung
Die Betriebsanleitung dient der Montage, sowie dem Benutzer des Geräts. Sie ist immer im Lieferumfang enthalten.
Die Montage und der Anschluss darf nur durch eine Person mit einer angemessenen Berufsqualifi kation, nach die-
ser Bedienungsanleitung und Funktionen des Gerätes und unter Beachtung aller gültigen Vorschriften ausgeführt
werden. Die störungsfreie Funktion des Gerätes hängt auch von Transport, Lagerung und Handhabung ab. Falls Sie
irgendwelche Anzeichen von Beschädigung, Verformung, Fehlfunktionen oder Fehlteilen feststellen, ie das Gerät
nicht und wenden sich an den Verkäufer. Es ist notwendig, dieses Produkt und Teile davon als Elektronikschrott
zu behandeln, nachdem seine Lebensdauer beendet ist. Vor Beginn der Montage ist sicherzustellen, dass alle
Leitungen, miteinander verbundenen Teilen oder Anschlüsse spannungsfrei sind. Während der Montage und der
Wartung sind die Sicherheitsvorschriften, Normen, Richtlinien für die Arbeit mit elektrischen Geräten zu beachten.
Berühren Sie keine Teile des Gerätes, die mit Energie versorgt werden - Lebensgefahr. Aufgrund der Sendeleistung
des RFSignals, beachten Sie den geeigneten Montageort der RF-Komponenten in einem Gebäude, in dem die Ins-
tallation stattfi ndet. RF Control ist nur für die Montage im Innenbereich geeignet. Geräte sind nicht für die Montage
in Außenbereichen und Feuchträumen geeignet. RF Control Komponenten dürfen nicht in Metallschalttafeln und
in Kunststoff - Schalttafeln mit Metalltür installiert werden - Die Durchlässigkeit des RF-Signals ist dann nicht gege-
ben. RF Control ist nicht für Aufzüge geeignet - das RF Signal kann gestört und abgeschirmt werden, die Batterie
des Emfängers verliert schnell die Leistung etc. - dieses verhindert die Steuerung durch eine Steuerungseinheit.
Achtung:
Bei der Installation Aktoren iNELS RF Control muss es der Mindestabstand 1 cm geachtet sein.
Zwischen aufeinanderfolgenden Befehlseingaben sollte mindesten 1s Abstand liegen.