iNels Elko AirTM-100S Скачать руководство пользователя страница 3

3 / 4

UPLINK

DOWNLINK

UPLINK / DOWNLINK

Note

Graf

Byte

0

1

2

3

4

5

6

7

Function

Bit

7

6 - 0

7

6

5

4

3

2

1

0

S0

First message 

fl ag: 

1 - fi rst message 

0 - others

0x01

Reserved for future use

Tamper: 

1 - opened

0 - closed

Battery: 

1 - low level

0 - OK

Coun-

ter[0]

Coun-

ter[1]

Coun-

ter[2]

Coun-

ter[3]

*Version 

FW

*Subver-

sion FW

ENERGY_METERING

0x02

Coun-

ter[0]

Coun-

ter[1]

Coun-

ter[2]

Coun-

ter[3]

*Version 

FW

*Subver-

sion FW

Function

0

1

2

3

4

5

6

7

S0

0x01

Heartbeat period

0x00

0x00

Threshold 1H

Threshold 1L

Threshold 2H

Threshold 2L

ENERGY_METERING

0x02

Heartbeat period

0x00

0x00

Threshold 1H

Threshold 1L

0x00

0x00

Heartbeat period

0 - 127 [x min]

heartbeat message period

128 - 255 [(x - 127) h]

Threshold 1H 1L

0 - 65535

Input 1 - pulses threshold

Threshold 2H 2L

0 - 65535

Input 2 - pulses threshold

Name

Unit

Example

Counter 

[0 – 3]

pulse

Counter[0] = 0x01
Counter[1] = 0x02
Counter[2] = 0x03
Counter[3] = 0x04

Counter = 0x01020304

= 16909060 pulses

Отзывы: