iNels Elco AirSOU-100NB Скачать руководство пользователя страница 2

2 / 3

1

3

Click!

2

+

-

Placement recommendations

•  For the correct operation of the sensor, it is necessary to eliminate all disturbing light 

sources in the sensed area.

•  Before mounting, check the range and location of the product and the antenna. Ensure 

the correct location - see Warning.

•  The sensor is suitable for outdoor use. Operating conditions are consistent with con-

ventional chemically non-aggressive environments.

•  The recommended working position is vertical; the light guide should point down-

wards or upwards.

•  For proper functionality, the light guide should be kept clean and uncovered (occasio-

nal cleaning of the light pipe without the use of chemicals).

Inappropriate location

•  Places where distortion may occur (the light pipe must not be illuminated by direct 

light) - below the lamp, where there is a sudden change in lighting intensity (e.g. fl a-
shing advertising), etc.

•  Very dusty environment.

•  In the case of a light guide installation, the light guide should not be exposed to wea-

thering (sensing distortion may occur due to rain / snow).

When handling a device unboxed it is important to avoid contact with 
liquids. avoid unnecessary contact with the components of the device. Do 
not touch the metal objects inside the unit.

Safe handling

Restart

•  Open the cover. Power interruption (remove the battery from the device).

•  Press SET> 1min.

•  Connect power (insert battery). Close the cover.

Replacing batteries

1. Using a fl at-blade screwdriver gradually slide it into one and then the other groove in 

the lid and swing open the cover.

2. Remove the discharged battery and insert a new battery into the holder. Beware of 

polarity. Both LEDs will fl ash 3 times (see device status indication).

3. Replace and snap the front cover.

Notice:

Only use batteries designed for this product correctly inserted in the device! Immediately replace 
weak batteries with new ones. Do not use new and used batteries together. If necessary, clean the 
battery and contacts prior to using. Avoid battery shorts!  Do not dispose of batteries in water or 
fi re. Do not dismantle batteries, do not try to charge them and protect them from extreme heating 
- danger of leakage! Upon contact with acid, immediately rinse the aff ected area with a stream of 
water and seek medical attention. Keep batteries out of the reach of children.  If it is suspected that 
the battery has been swallowed or somehow placed inside the body, consult a doctor immediately. 
Give the doctor information about the type of battery (from battery case, device or its manual, etc.) 
to determine the chemical composition of the battery. Batteries must be recycled or returned to an 
appropriate location (e.g. collection container) in accordance with local legal provisions.

power supply (external or battery), 

reset unit

Connection to the network

SIM Error - cannot be loaded (SIM 

card insertion and rotation check) / 

or NB-IoT MODULE error

start unit ok

opening the cover

test, cancel, „long press“

setting mode (signaling of meas-

urement) 

light measurement

sending / receiving data

it is necessary to disconnect the power sup-

ply (external or battery), after 60 seconds 

after the LED goes out, insert the battery

the battery may be discharged

a discharged battery or a damaged 

product

Device states

Unit initialization

Start  

Search for BTS *2)

SIM ERR *2)

ERR *2)

Successful network connection *2)

Measurement

Tamper

SET button short press (< 2s)

SET button longer press 

(>2s / <5s)

Measurement signaling *1)

Communication

Communication 

Other known states

Does not respond to the SET 

button

The unit is still in reset

The unit does not respond even 

after removal insert the battery

Indication

3 x R + G blinks

2 x fl ashes  R (2xR _ 2xR _ ...)

5 x fl ashes  R (repeatedly)

1 x fl ashes  R

without indication

1 x fl ashes  G

2 x fl ashes  G

1 x fl ashes  G 

1 x fl ashes  R

any LED lights

still indicates start

without indication

When the tamper is pressed, the LED is 
turned off !
Note:
R... LED red
G... LED green

* 1) Indicates only when you press SET 

> 2 s (setting mode)

* 2) Planned

UPLINK

Byte

0-14

15

16

17

18

19

20

21

Bit

7

6

5

4

3

2

1

0

HEARTBEAT

IMEI

1

0x10

Reserved for future use

Tamper: 

1 - opened

0 - closed

Battery: 

1 - low level

0 - OK

Illuminance[0]

Illuminance[1]

Illumi-

nance[2]

Illumi-

nance[3]

START 3

Version 

FW

Subversion FW

Version FW 

Narrowband

Subversion FW 

Narrowband

Name

Unit

Example

Illuminance[0 – 3]

[100*] lx

Illuminance[0] = 0x00
Illuminance[1] = 0x00
Illuminance[2] = 0x07

Illuminance[3] = 0xD0

Illuminance = 0x000007D0

= 2000 / 100 = 20 lx